A Carnot cycle is an ideal thermodynamic cycle proposed by French physicist Sadi Carnot in 1824 and expanded upon by others in the 1830s and 1840s. By Carnot's theorem, it provides an upper limit on the efficiency of any classical thermodynamic engine during the conversion of heat into work, or conversely, the efficiency of a refrigeration system in creating a temperature difference through the application of work to the system.
In a Carnot cycle, a system or engine transfers energy in the form of heat between two thermal reservoirs at temperatures and
(referred to as the hot and cold reservoirs, respectively), and a part
of this transferred energy is converted to the work done by the system.
The cycle is reversible, and there is no generation of entropy. (In other words, entropy is conserved;
entropy is only transferred between the thermal reservoirs and the
system without gain or loss of it.) When work is applied to the system,
heat moves from the cold to hot reservoir (heat pump or refrigeration). When heat moves from the hot to the cold reservoir, the system applies work to the environment. The work
done by the system or engine to the environment per Carnot cycle
depends on the temperatures of the thermal reservoirs and the entropy
transferred from the hot reservoir to the system per cycle such as , where is heat transferred from the hot reservoir to the system per cycle.
Stages
A Carnot
cycle as an idealized thermodynamic cycle performed by a heat engine
(Carnot heat engine) consists of the following steps.
Isothermal expansion. Heat (as an energy) is transferred reversibly from hot temperature reservoir at constant temperature TH to the gas at temperature infinitesimally less than TH (to allow heat transfer to the gas without practically changing the gas temperature so isothermal heat addition or absorption). During this step (1 to 2 on Figure 1, A to B in Figure 2),
the gas is thermally in contact with the hot temperature reservoir
(while thermally isolated from the cold temperature reservoir) and the
gas is allowed to expand, doing work on the surroundings by gas pushing
up the piston (stage 1 figure, right). Although the pressure drops from
points 1 to 2 (figure 1) the temperature of the gas does not change
during the process because the heat transferred from the hot temperature
reservoir to the gas is exactly used to do work on the surroundings by
the gas, so no gas internal energy changes (no gas temperature change
for an ideal gas). Heat QH > 0 is absorbed from the hot temperature reservoir, resulting in an increase in the entropy of the gas by the amount .
Isentropic (reversible adiabatic) expansion of the gas (isentropic work output). For this step (2 to 3 on Figure 1, B to C in Figure 2) the gas in the engine is thermally insulated from both the hot and cold reservoirs, thus they neither gain nor lose heat, an 'adiabatic'
process. The gas continues to expand with reduction of its pressure,
doing work on the surroundings (raising the piston; stage 2 figure,
right), and losing an amount of internal energy equal to the work done.
The gas expansion without heat input causes the gas to cool to the
"cold" temperature (by losing its internal energy), that is
infinitesimally higher than the cold reservoir temperature TC. The entropy remains unchanged as no heat Q transfers (Q = 0) between the system (the gas) and its surroundings, so an isentropic process, meaning no entropy change in the process).
Isothermal compression. Heat transferred reversibly to low temperature reservoir at constant temperature TC (isothermal heat rejection). In this step (3 to 4 on Figure 1, C to D on Figure 2), the gas in the engine is in thermal contact with the cold reservoir at temperature TC
(while thermally isolated from the hot temperature reservoir) and the
gas temperature is infinitesimally higher than this temperature (to
allow heat transfer from the gas to the cold reservoir without
practically changing the gas temperature). The surroundings do work on
the gas, pushing the piston down (stage 3 figure, right). An amount of
energy earned by the gas from this work exactly transfers as a heat
energy QC < 0 (negative as leaving from the system, according to the universal convention in thermodynamics) to the cold reservoir so the entropy of the system decreases by the amount . because the isothermal compression decreases the multiplicity of the gas.
Isentropic compression. (4 to 1 on Figure 1, D to A on Figure 2)
Once again the gas in the engine is thermally insulated from the hot
and cold reservoirs, and the engine is assumed to be frictionless and
the process is slow enough, hence reversible. During this step, the
surroundings do work on the gas, pushing the piston down further (stage 4
figure, right), increasing its internal energy, compressing it, and
causing its temperature to rise back to the temperature infinitesimally
less than TH due solely to the work added to the
system, but the entropy remains unchanged. At this point the gas is in
the same state as at the start of step 1.
In this case, since it is a reversible thermodynamic cycle (no net change in the system and its surroundings per cycle)
or,
This is true as and are both smaller in magnitude and in fact are in the same ratio as .
The pressure–volume graph
When a Carnot cycle is plotted on a pressure–volume diagram (Figure 1),
the isothermal stages follow the isotherm lines for the working fluid,
the adiabatic stages move between isotherms, and the area bounded by the
complete cycle path represents the total work that can be done during
one cycle. From point 1 to 2 and point 3 to 4 the temperature is
constant (isothermal process). Heat transfer from point 4 to 1 and point
2 to 3 are equal to zero (adiabatic process).
The behavior of a Carnot engine or refrigerator is best understood by using a temperature–entropy diagram (T–S diagram), in which the thermodynamic state is specified by a point on a graph with entropy (S) as the horizontal axis and temperature (T) as the vertical axis (Figure 2).
For a simple closed system (control mass analysis), any point on the
graph represents a particular state of the system. A thermodynamic
process is represented by a curve connecting an initial state (A) and a
final state (B). The area under the curve is:
(1)
which is the amount heat transferred in the process. If the process
moves the system to greater entropy, the area under the curve is the
amount of heat absorbed by the system in that process; otherwise, it is
the amount of heat removed from or leaving from the system. For any
cyclic process, there is an upper portion of the cycle and a lower
portion. In T-S diagrams for a clockwise cycle, the area
under the upper portion will be the energy absorbed by the system during
the cycle, while the area under the lower portion will be the energy
removed from the system during the cycle. The area inside the cycle is
then the difference between the two (the absorbed net heat energy), but
since the internal energy of the system must have returned to its
initial value, this difference must be the amount of work done by the
system per cycle. Referring to Figure 1, mathematically, for a reversible process, we may write the amount of work done over a cyclic process as:
(2)
Since dU is an exact differential, its integral over any closed loop is zero and it follows that the area inside the loop on a T–S
diagram is equal to the total work performed by the system on the
surroundings if the loop is traversed in a clockwise direction, and is
equal to the total work done on the system by the surroundings as the
loop is traversed in a counterclockwise direction.
The Carnot cycle
Evaluation of the above integral is particularly simple for a Carnot cycle. The amount of energy transferred as work is
The total amount of heat transferred from the hot reservoir to the system (in the isothermal expansion) will be
and the total amount of heat transferred from the system to the cold reservoir (in the isothermal compression) will be
Due to energy conservation, the net heat transferred, , is equal to the work performed
The efficiency is defined to be:
(3)
where
W is the work done by the system (energy exiting the system as work),
< 0 is the heat taken from the system (heat energy leaving the system),
> 0 is the heat put into the system (heat energy entering the system),
The expression with the temperature can be derived from the expressions above with the entropy: and . Since , a minus sign appears in the final expression for .
This is the Carnot heat engine working efficiency definition as the
fraction of the work done by the system to the thermal energy received
by the system from the hot reservoir per cycle. This thermal energy is
the cycle initiator.
Reversed Carnot cycle
A
Carnot heat-engine cycle described is a totally reversible cycle. That
is, all the processes that compose it can be reversed, in which case it
becomes the Carnot heat pump and refrigeration cycle.
This time, the cycle remains exactly the same except that the
directions of any heat and work interactions are reversed. Heat is
absorbed from the low-temperature reservoir, heat is rejected to a
high-temperature reservoir, and a work input is required to accomplish
all this. The P–V diagram of the reversed Carnot cycle is
the same as for the Carnot heat-engine cycle except that the directions
of the processes are reversed.
It can be seen from the above diagram that for any cycle operating between temperatures and , none can exceed the efficiency of a Carnot cycle.
Carnot's theorem is a formal statement of this fact: No
engine operating between two heat reservoirs can be more efficient than a
Carnot engine operating between those same reservoirs. Thus, Equation 3
gives the maximum efficiency possible for any engine using the
corresponding temperatures. A corollary to Carnot's theorem states that:
All reversible engines operating between the same heat reservoirs are equally efficient.
Rearranging the right side of the equation gives what may be a more
easily understood form of the equation, namely that the theoretical
maximum efficiency of a heat engine equals the difference in temperature
between the hot and cold reservoir divided by the absolute temperature
of the hot reservoir. Looking at this formula an interesting fact
becomes apparent: Lowering the temperature of the cold reservoir will
have more effect on the ceiling efficiency of a heat engine than raising
the temperature of the hot reservoir by the same amount. In the real
world, this may be difficult to achieve since the cold reservoir is
often an existing ambient temperature.
In other words, the maximum efficiency is achieved if and only if
entropy does not change per cycle. An entropy change per cycle is made,
for example, if there is friction leading to dissipation of work into heat. In that case, the cycle is not reversible and the Clausius theorem becomes an inequality rather than an equality. Otherwise, since entropy is a state function,
the required dumping of heat into the environment to dispose of excess
entropy leads to a (minimal) reduction in efficiency. So Equation 3 gives the efficiency of any reversibleheat engine.
In mesoscopic heat engines, work per cycle of operation in
general fluctuates due to thermal noise. If the cycle is performed
quasi-statically, the fluctuations vanish even on the mesoscale.
However, if the cycle is performed faster than the relaxation time of
the working medium, the fluctuations of work are inevitable.
Nevertheless, when work and heat fluctuations are counted, an exact
equality relates the exponential average of work performed by any heat
engine to the heat transfer from the hotter heat bath.
Carnot realized that, in reality, it is not possible to build a thermodynamically reversible engine. So, real heat engines are even less efficient than indicated by Equation 3.
In addition, real engines that operate along the Carnot cycle style
(isothermal expansion / isentropic expansion / isothermal compression /
isentropic compression) are rare. Nevertheless, Equation 3 is extremely useful for determining the maximum efficiency that could ever be expected for a given set of thermal reservoirs.
Although Carnot's cycle is an idealization, Equation 3 as the expression of the Carnot efficiency is still useful. Consider the average temperatures,
at which the first integral is over a part of a cycle where heat goes
into the system and the second integral is over a cycle part where heat
goes out from the system. Then, replace TH and TC in Equation 3 by ⟨TH⟩ and ⟨TC⟩, respectively, to estimate the efficiency a heat engine.
For the Carnot cycle, or its equivalent, the average value ⟨TH⟩ will equal the highest temperature available, namely TH, and ⟨TC⟩ the lowest, namely TC. For other less efficient thermodynamic cycles, ⟨TH⟩ will be lower than TH, and ⟨TC⟩ will be higher than TC. This can help illustrate, for example, why a reheater or a regenerator
can improve the thermal efficiency of steam power plants and why the
thermal efficiency of combined-cycle power plants (which incorporate gas
turbines operating at even higher temperatures) exceeds that of
conventional steam plants. The first prototype of the diesel engine was based on the Carnot cycle.
Carnot heat engine as an impractical macroscopic construct
A
Carnot heat engine is a heat engine performing a Carnot cycle, and its
realization on a macroscopic scale is impractical. For example, for the isothermal expansion part of the Carnot cycle, the following conditions must be satisfied simultaneously at every step in the expansion:
The hot reservoir temperature TH is infinitesimally higher than the system gas temperature T so heat flow (energy transfer) from the hot reservoir to the gas is made without increasing T (via infinitesimal work on the surroundings by the gas as another energy transfer); if TH is significantly higher than T, then T
may be not uniform through the gas so the system would deviate from
thermal equilibrium as well as not being a reversible process (i.e. not a
Carnot cycle) or T might increase noticeably so it would not be an isothermal process.
The force externally applied on the piston (opposite to the internal
force on the piston by the gas) needs to be infinitesimally reduced
somehow. Without this external assistance, it would not be possible to
follow a gas PV (Pressure-Volume) curve downward at a constant T since following this curve means that the gas-to-piston force decreases (P
decreases) as the volume expands (the piston moves outward). If this
assistance is so strong that the volume expansion is significant, the
system may deviate from thermal equilibrium as well as not being a
reversible process (i.e. not a Carnot cycle).
These (and other) "infinitesimal" requirements make the Carnot cycle
take an infinite amount of time. Other practical requirements that make
the Carnot cycle hard to realize (e.g., fine control of the gas, thermal
contact with the surroundings including high and low temperature
reservoirs), so the Carnot engine should be thought as the theoretical
limit of macroscopic scale heat engines rather than a practical device
that could ever be built.
Tissue engineering is a biomedical engineering discipline that uses a combination of cells, engineering, materials methods, and suitable biochemical and physicochemical factors to restore, maintain, improve, or replace different types of biological tissues. Tissue engineering often involves the use of cells placed on tissue scaffolds
in the formation of new viable tissue for a medical purpose but is not
limited to applications involving cells and tissue scaffolds. While it
was once categorized as a sub-field of biomaterials, having grown in scope and importance it can be considered as a field of its own.
While most definitions of tissue engineering cover a broad range of
applications, in practice the term is closely associated with
applications that repair or replace portions of or whole tissues (i.e. bone, cartilage, blood vessels, bladder, skin, muscle
etc.). Often, the tissues involved require certain mechanical and
structural properties for proper functioning. The term has also been
applied to efforts to perform specific biochemical functions using cells within an artificially-created support system (e.g. an artificial pancreas, or a bio artificial liver). The term regenerative medicine is often used synonymously with tissue engineering, although those involved in regenerative medicine place more emphasis on the use of stem cells or progenitor cells to produce tissues.
Overview
A commonly applied definition of tissue engineering, as stated by Langer and Vacanti, is "an interdisciplinary
field that applies the principles of engineering and life sciences
toward the development of biological substitutes that restore, maintain,
or improve [Biological tissue] function or a whole organ".
In addition, Langer and Vacanti also state that there are three main
types of tissue engineering: cells, tissue-inducing substances, and a
cells + matrix approach (often referred to as a scaffold). Tissue
engineering has also been defined as "understanding the principles of
tissue growth, and applying this to produce functional replacement
tissue for clinical use".
A further description goes on to say that an "underlying supposition of
tissue engineering is that the employment of natural biology of the
system will allow for greater success in developing therapeutic
strategies aimed at the replacement, repair, maintenance, or enhancement
of tissue function".
Developments in the multidisciplinary field of tissue engineering
have yielded a novel set of tissue replacement parts and implementation
strategies. Scientific advances in biomaterials, stem cells, growth and differentiation factors, and biomimetic
environments have created unique opportunities to fabricate or improve
existing tissues in the laboratory from combinations of engineered
extracellular matrices ("scaffolds"), cells, and biologically active
molecules. Among the major challenges now facing tissue engineering is
the need for more complex functionality, biomechanical stability, and
vascularization in laboratory-grown tissues destined for
transplantation.
Etymology
The
historic origin of the term is unclear as the definition of the word
has changed throughout the past few decades. The term first appeared in a
1984 publication that described the organization of an endothelium-like
membrane on the surface of a long-implanted, synthetic ophthalmic prosthesis.
The first modern use of the term as recognized today was in 1985 by the researcher, physiologist and bioengineer Yuan-Cheng Fung of the Engineering Research Center. He proposed the joining of the terms tissue (in reference to the fundamental relationship between cells and organs) and engineering (in reference to the field of modification of said tissues). The term was officially adopted in 1987.
History
Ancient era (pre-17th century)
A
rudimentary understanding of the inner workings of human tissues may
date back further than most would expect. As early as the Neolithic
period, sutures were being used to close wounds and aid in healing.
Later on, societies such as ancient Egypt developed better materials for
sewing up wounds such as linen sutures. Around 2500 BC in ancient
India, skin grafts were developed by cutting skin from the buttock and
suturing it to wound sites in the ear, nose, or lips. Ancient Egyptians
often would graft skin from corpses onto living humans and even
attempted to use honey as a type of antibiotic and grease as a
protective barrier to prevent infection. In the 1st and 2nd centuries
AD, Gallo-Romans developed wrought iron implants and dental implants
could be found in ancient Mayans.
Enlightenment (17th century–19th century)
While
these ancient societies had developed techniques that were way ahead of
their time, they still lacked a mechanistic understanding of how the
body was reacting to these procedures. This mechanistic approach came
along in tandem with the development of the empirical method of science
pioneered by René Descartes. Sir Isaac Newton began to describe the body
as a "physiochemical machine" and postured that disease was a breakdown
in the machine. In the 17th century, Robert Hooke discovered the cell
and a letter from Benedict de Spinoza brought forward the idea of the
homeostasis between the dynamic processes in the body. Hydra experiments
performed by Abraham Trembley in the 18th century began to delve into
the regenerative capabilities of cells. During the 19th century, a
better understanding of how different metals reacted with the body led
to the development of better sutures and a shift towards screw and plate
implants in bone fixation. Further, it was first hypothesized in the
mid-1800s that cell-environment interactions and cell proliferation were
vital for tissue regeneration.
Modern era (20th and 21st centuries)
As
time progresses and technology advances, there is a constant need for
change in the approach researchers take in their studies. Tissue
engineering has continued to evolve over centuries. In the beginning
people used to look at and use samples directly from human or animal
cadavers. Now, tissue engineers have the ability to remake many of the
tissues in the body through the use of modern techniques such as
microfabrication and three-dimensional bioprinting in conjunction with
native tissue cells/stem cells. These advances have allowed researchers
to generate new tissues in a much more efficient manner. For example,
these techniques allow for more personalization which allow for better
biocompatibility, decreased immune response, cellular integration, and
longevity. There is no doubt that these techniques will continue to
evolve, as we have continued to see microfabrication and bioprinting
evolve over the past decade.
In 1960, Wichterle and Lim were the first to publish experiments
on hydrogels for biomedical applications by using them in contact lens
construction. Work on the field developed slowly over the next two
decades, but later found traction when hydrogels were repurposed for
drug delivery. In 1984, Charles Hull developed bioprinting by converting
a Hewlett-Packard inkjet printer into a device capable of depositing
cells in 2-D. Three dimensional (3-D) printing is a type of additive
manufacturing which has since found various applications in medical
engineering, due to its high precision and efficiency. With biologist
James Thompson's development of first human stem cell lines in 1998
followed by transplantation of first laboratory-grown internal organs in
1999 and creation of the first bioprinter in 2003 by the University of
Missouri when they printed spheroids without the need of scaffolds, 3-D
bioprinting became more conventionally used in medical field than ever
before. So far, scientists have been able to print mini organoids and
organs-on-chips that have rendered practical insights into the functions
of a human body. Pharmaceutical companies are using these models to
test drugs before moving on to animal studies. However, a fully
functional and structurally similar organ hasn't been printed yet. A
team at University of Utah has reportedly printed ears and successfully
transplanted those onto children born with defects that left their ears
partially developed.
Today hydrogels are considered the preferred choice of bio-inks
for 3-D bioprinting since they mimic cells' natural ECM while also
containing strong mechanical properties capable of sustaining 3-D
structures. Furthermore, hydrogels in conjunction with 3-D bioprinting
allow researchers to produce different scaffolds which can be used to
form new tissues or organs. 3-D printed tissues still face many
challenges such as adding vasculature. Meanwhile, 3-D printing parts of
tissues definitely will improve our understanding of the human body,
thus accelerating both basic and clinical research.
Examples
As defined by Langer and Vacanti,
examples of tissue engineering fall into one or more of three
categories: "just cells," "cells and scaffold," or "tissue-inducing
factors."
In vitro meat: Edible artificial animal muscle tissue cultured in vitro.
Bioartificial liver device, "Temporary Liver", Extracorporeal Liver Assist Device (ELAD): The human hepatocyte cell line (C3A line) in a hollow fiber bioreactor
can mimic the hepatic function of the liver for acute instances of
liver failure. A fully capable ELAD would temporarily function as an
individual's liver, thus avoiding transplantation and allowing
regeneration of their own liver.
Artificial pancreas: Research involves using islet cells to regulate the body's blood sugar, particularly in cases of diabetes
. Biochemical factors may be used to cause human pluripotent stem cells
to differentiate (turn into) cells that function similarly to beta cells, which are in an islet cell in charge of producing insulin.
Artificial bladders: Anthony Atala (Wake Forest University)
has successfully implanted artificial bladders, constructed of cultured
cells seeded onto a bladder-shaped scaffold, into seven out of
approximately 20 human test subjects as part of a long-term experiment.
Cartilage: lab-grown cartilage, cultured in vitro on a scaffold, was successfully used as an autologous transplant to repair patients' knees.
Scaffold-free cartilage: Cartilage generated without the use of
exogenous scaffold material. In this methodology, all material in the
construct is cellular produced directly by the cells.
Bioartificial heart: Doris Taylor's lab constructed a biocompatible rat heart by re-cellularising a de-cellularised rat heart. This scaffold and cells were placed in a bioreactor, where it matured to become a partially or fully transplantable organ. the work was called a "landmark". The lab first stripped the cells away from a rat heart (a process called "decellularization") and then injected rat stem cells into the decellularized rat heart.
Tissue-engineered blood vessels: Blood vessels that have been grown in a lab and can be used to repair damaged blood vessels without eliciting an immune response.
Tissue engineered blood vessels have been developed by many different
approaches. They could be implanted as pre-seeded cellularized blood
vessels, as acellular vascular grafts made with decellularized vessels or synthetic vascular grafts.
Artificial skin constructed from human skin cells embedded in a hydrogel, such as in the case of bio-printed constructs for battlefield burn repairs.
Artificial bone marrow: Bone marrow cultured in vitro to be transplanted serves as a "just cells" approach to tissue engineering.
Tissue engineered bone: A structural matrix can be composed of
metals such as titanium, polymers of varying degradation rates, or
certain types of ceramics. Materials are often chosen to recruit osteoblasts to aid in reforming the bone and returning biological function. Various types of cells can be added directly into the matrix to expedite the process.
Laboratory-grown penis:
Decellularized scaffolds of rabbit penises were recellularised with
smooth muscle and endothelial cells. The organ was then transplanted to
live rabbits and functioned comparably to the native organ, suggesting
potential as treatment for genital trauma.
Cells are one of the main components for the success of tissue
engineering approaches. Tissue engineering uses cells as strategies for
creation/replacement of new tissue. Examples include fibroblasts used for skin repair or renewal, chondrocytes used for cartilage repair (MACI–FDA approved product), and hepatocytes used in liver support systems
Cells can be used alone or with support matrices for tissue
engineering applications. An adequate environment for promoting cell
growth, differentiation, and integration with the existing tissue is a
critical factor for cell-based building blocks.
Manipulation of any of these cell processes create alternative avenues
for the development of new tissue (e.g., reprogramming of somatic cells,
vascularization).
Isolation
Techniques
for cell isolation depend on the cell source. Centrifugation and
apheresis are techniques used for extracting cells from biofluids (e.g.,
blood). Whereas digestion processes, typically using enzymes to remove
the extracellular matrix (ECM), are required prior to centrifugation or
apheresis techniques to extract cells from tissues/organs. Trypsin and
collagenase are the most common enzymes used for tissue digestion. While
trypsin is temperature dependent, collagenase is less sensitive to
changes in temperature.
Cell sources
Primary cells are those directly isolated from host tissue.
These cells provide an ex-vivo model of cell behavior without any
genetic, epigenetic, or developmental changes; making them a closer
replication of in-vivo conditions than cells derived from other methods.
This constraint however, can also make studying them difficult. These
are mature cells, often terminally differentiated, meaning that for many
cell types proliferation is difficult or impossible. Additionally, the
microenvironments these cells exist in are highly specialized, often
making replication of these conditions difficult.
Secondary cells A portion of cells from a primary culture
is moved to a new repository/vessel to continue being cultured. Medium
from the primary culture is removed, the cells that are desired to be
transferred are obtained, and then cultured in a new vessel with fresh
growth medium.
A secondary cell culture is useful in order to ensure that cells have
both the room and nutrients that they require to grow. Secondary
cultures are most notably used in any scenario in which a larger
quantity of cells than can be found in the primary culture is desired.
Secondary cells share the constraints of primary cells (see above) but
have an added risk of contamination when transferring to a new vessel.
Genetic classifications of cells
Autologous:
The donor and the recipient of the cells are the same individual. Cells
are harvested, cultured or stored, and then reintroduced to the host.
As a result of the host's own cells being reintroduced, an antigenic
response is not elicited. The body's immune system recognizes these
re-implanted cells as its own, and does not target them for attack.
Autologous cell dependence on host cell health and donor site morbidity
may be deterrents to their use. Adipose-derived and bone marrow-derived
mesenchymal stem cells are commonly autologous in nature, and can be
used in a myriad of ways, from helping repair skeletal tissue to
replenishing beta cells in diabetic patients.
Allogenic: Cells are obtained from the body of a donor of the
same species as the recipient. While there are some ethical constraints
to the use of human cells for in vitro studies (i.e. human brain tissue
chimera development),
the employment of dermal fibroblasts from human foreskin demonstrates
an immunologically safe and thus a viable choice for allogenic tissue
engineering of the skin.
Xenogenic: These cells are derived isolated cells from alternate
species from the recipient. A notable example of xenogeneic tissue
utilization is cardiovascular implant construction via animal cells.
Chimeric human-animal farming raises ethical concerns around the
potential for improved consciousness from implanting human organs in
animals.
Syngeneic or isogenic: These cells describe those borne from
identical genetic code. This imparts an immunologic benefit similar to
autologous cell lines (see above).[32]
Autologous cells can be considered syngenic, but the classification
also extends to non-autologously derived cells such as those from an
identical twin, from genetically identical (cloned) research models, or induced stem cells (iSC)[33] as related to the donor.
Stem cells
Stem cells
are undifferentiated cells with the ability to divide in culture and
give rise to different forms of specialized cells. Stem cells are
divided into "adult" and "embryonic" stem cells according to their
source. While there is still a large ethical debate related to the use
of embryonic stem cells, it is thought that another alternative source –
induced pluripotent stem cells – may be useful for the repair of diseased or damaged tissues, or may be used to grow new organs.
Totipotent
cells are stem cells which can divide into further stem cells or
differentiate into any cell type in the body, including extra-embryonic
tissue.
Pluripotent cells are stem cells which can differentiate into any cell type in the body except extra-embryonic tissue. induced pluripotent stem cells
(iPSCs) are subclass of pluripotent stem cells resembling embryonic
stem cells (ESCs) that have been derived from adult differentiated
cells. iPSCs are created by altering the expression of transcriptional
factors in adult cells until they become like embryonic stem cells.[citation needed]
Multipotent stem cells can be differentiated into any cell within the same class, such as blood or bone. A common example of multipotent cells is Mesenchymal stem cells (MSCs).
Scaffolds
Scaffolds
are materials that have been engineered to cause desirable cellular
interactions to contribute to the formation of new functional tissues
for medical purposes. Cells are often 'seeded' into these structures
capable of supporting three-dimensional tissue formation. Scaffolds mimic the extracellular matrix of the native tissue, recapitulating the in vivo
milieu and allowing cells to influence their own microenvironments.
They usually serve at least one of the following purposes: allowing cell
attachment and migration, delivering and retaining cells and
biochemical factors, enabling diffusion of vital cell nutrients and
expressed products, and exerting certain mechanical and biological
influences to modify the behaviour of the cell phase.
In 2009, an interdisciplinary team led by the thoracic surgeon Thorsten Walles
implanted the first bioartificial transplant that provides an innate
vascular network for post-transplant graft supply successfully into a
patient awaiting tracheal reconstruction.
To achieve the goal of tissue reconstruction, scaffolds must meet
some specific requirements. High porosity and adequate pore size are
necessary to facilitate cell seeding and diffusion throughout the whole
structure of both cells and nutrients. Biodegradability
is often an essential factor since scaffolds should preferably be
absorbed by the surrounding tissues without the necessity of surgical
removal. The rate at which degradation occurs has to coincide as much as
possible with the rate of tissue formation: this means that while cells
are fabricating their own natural matrix structure around themselves,
the scaffold is able to provide structural integrity within the body and
eventually it will break down leaving the newly formed tissue which
will take over the mechanical load. Injectability is also important for
clinical uses.
Recent research on organ printing is showing how crucial a good control
of the 3D environment is to ensure reproducibility of experiments and
offer better results.
Materials
Material
selection is an essential aspect of producing a scaffold. The
materials utilized can be natural or synthetic and can be biodegradable
or non-biodegradable. Additionally, they must be biocompatible, meaning
that they don't cause any adverse effects to cells. Silicone, for example, is a synthetic, non-biodegradable material commonly used as a drug delivery material, while gelatin is a biodegradable, natural material commonly used in cell-culture scaffolds
The material needed for each application is different, and
dependent on the desired mechanical properties of the material. Tissue
engineering of long bone defects for example, will require a rigid
scaffold with a compressive strength similar to that of cortical bone
(100-150 MPa), which is much higher compared to a scaffold for skin
regeneration.
There are a few versatile synthetic materials used for many
different scaffold applications. One of these commonly used materials is
polylactic acid (PLA), a synthetic polymer. PLA – polylactic acid. This is a polyester which degrades within the human body to form lactic acid, a naturally occurring chemical which is easily removed from the body. Similar materials are polyglycolic acid (PGA) and polycaprolactone (PCL): their degradation mechanism is similar to that of PLA, but PCL degrades slower and PGA degrades faster.
PLA is commonly combined with PGA to create poly-lactic-co-glycolic
acid (PLGA). This is especially useful because the degradation of PLGA
can be tailored by altering the weight percentages of PLA and PGA: More
PLA – slower degradation, more PGA – faster degradation. This
tunability, along with its biocompatibility, makes it an extremely
useful material for scaffold creation.
Scaffolds may also be constructed from natural materials: in particular different derivatives of the extracellular matrix have been studied to evaluate their ability to support cell growth. Protein based materials – such as collagen, or fibrin, and polysaccharidic materials- like chitosan or glycosaminoglycans (GAGs), have all proved suitable in terms of cell compatibility. Among GAGs, hyaluronic acid, possibly in combination with cross linking agents (e.g. glutaraldehyde, water-soluble carbodiimide, etc.), is one of the possible choices as scaffold material.
Due to the covalent attachment of thiol groups to these polymers, they can crosslink via disulfide bond formation. The use of thiolated polymers (thiomers)
as scaffold material for tissue engineering was initially introduced at
the 4th Central European Symposium on Pharmaceutical Technology in Vienna 2001.
As thiomers are biocompatible, exhibit cellular mimicking properties
and efficiently support proliferation and differentiation of various
cell types, they are extensively used as scaffolds for tissue
engineering. Furthermore thiomers such as thiolated hyaluronic acid and thiolated chitosan were shown to exhibit wound healing properties and are subject of numerous clinical trials. Additionally, a fragment of an extracellular matrix protein, such as the RGD peptide, can be coupled to a non-bioactive material to promote cell attachment.
Another form of scaffold is decellularized tissue. This is a process
where chemicals are used to extracts cells from tissues, leaving just
the extracellular matrix. This has the benefit of a fully formed matrix
specific to the desired tissue type. However, the decellurised scaffold
may present immune problems with future introduced cells.
Synthesis
A number of different methods have been described in the literature
for preparing porous structures to be employed as tissue engineering
scaffolds. Each of these techniques presents its own advantages, but
none are free of drawbacks.
Nanofiber self-assembly
Molecular
self-assembly is one of the few methods for creating biomaterials with
properties similar in scale and chemistry to that of the natural in vivo extracellular matrix (ECM), a crucial step toward tissue engineering of complex tissues.
Moreover, these hydrogel scaffolds have shown superiority in in vivo
toxicology and biocompatibility compared to traditional macro-scaffolds
and animal-derived materials.
Textile technologies
These techniques include all the approaches that have been successfully employed for the preparation of non-woven meshes of different polymers. In particular, non-woven polyglycolide
structures have been tested for tissue engineering applications: such
fibrous structures have been found useful to grow different types of
cells. The principal drawbacks are related to the difficulties in
obtaining high porosity and regular pore size.
Solvent casting and particulate leaching
Solvent casting and particulate leaching
(SCPL) allows for the preparation of structures with regular porosity,
but with limited thickness. First, the polymer is dissolved into a
suitable organic solvent (e.g. polylactic acid could be dissolved into dichloromethane), then the solution is cast into a mold filled with porogen particles. Such porogen can be an inorganic salt like sodium chloride, crystals of saccharose, gelatin spheres or paraffin
spheres. The size of the porogen particles will affect the size of the
scaffold pores, while the polymer to porogen ratio is directly
correlated to the amount of porosity of the final structure. After the
polymer solution has been cast the solvent is allowed to fully
evaporate, then the composite structure in the mold is immersed in a
bath of a liquid suitable for dissolving the porogen: water in the case
of sodium chloride, saccharose and gelatin or an aliphatic solvent like hexane
for use with paraffin. Once the porogen has been fully dissolved, a
porous structure is obtained. Other than the small thickness range that
can be obtained, another drawback of SCPL lies in its use of organic
solvents which must be fully removed to avoid any possible damage to the
cells seeded on the scaffold.
Gas foaming
To
overcome the need to use organic solvents and solid porogens, a
technique using gas as a porogen has been developed. First, disc-shaped
structures made of the desired polymer are prepared by means of
compression molding using a heated mold. The discs are then placed in a
chamber where they are exposed to high pressure CO2
for several days. The pressure inside the chamber is gradually restored
to atmospheric levels. During this procedure the pores are formed by
the carbon dioxide molecules that abandon the polymer, resulting in a
sponge-like structure. The main problems resulting from such a technique
are caused by the excessive heat used during compression molding (which
prohibits the incorporation of any temperature labile material into the
polymer matrix) and by the fact that the pores do not form an
interconnected structure.
Emulsification freeze-drying
This
technique does not require the use of a solid porogen like SCPL. First,
a synthetic polymer is dissolved into a suitable solvent (e.g.
polylactic acid in dichloromethane) then water is added to the polymeric
solution and the two liquids are mixed in order to obtain an emulsion. Before the two phases can separate, the emulsion is cast into a mold and quickly frozen by means of immersion into liquid nitrogen. The frozen emulsion is subsequently freeze-dried
to remove the dispersed water and the solvent, thus leaving a
solidified, porous polymeric structure. While emulsification and
freeze-drying allow for a faster preparation when compared to SCPL
(since it does not require a time-consuming leaching step), it still
requires the use of solvents. Moreover, pore size is relatively small
and porosity is often irregular. Freeze-drying by itself is also a
commonly employed technique for the fabrication of scaffolds. In
particular, it is used to prepare collagen sponges: collagen is
dissolved into acidic solutions of acetic acid or hydrochloric acid that are cast into a mold, frozen with liquid nitrogen and then lyophilized.
Thermally induced phase separation
Similar
to the previous technique, the TIPS phase separation procedure requires
the use of a solvent with a low melting point that is easy to sublime.
For example, dioxane
could be used to dissolve polylactic acid, then phase separation is
induced through the addition of a small quantity of water: a
polymer-rich and a polymer-poor phase are formed. Following cooling
below the solvent melting point and some days of vacuum-drying to
sublime the solvent, a porous scaffold is obtained. Liquid-liquid phase
separation presents the same drawbacks of emulsification/freeze-drying.
Electrospinning
Electrospinning
is a highly versatile technique that can be used to produce continuous
fibers ranging in diameter from a few microns to a few nanometers. In a
typical electrospinning set-up, the desired scaffold material is
dissolved within a solvent and placed within a syringe. This solution is
fed through a needle and a high voltage is applied to the tip and to a
conductive collection surface. The buildup of electrostatic forces
within the solution causes it to eject a thin fibrous stream towards the
oppositely charged or grounded collection surface. During this process
the solvent evaporates, leaving solid fibers leaving a highly porous
network. This technique is highly tunable, with variation to solvent,
voltage, working distance (distance from the needle to collection
surface), flow rate of solution, solute concentration, and collection
surface. This allows for precise control of fiber morphology.
On a commercial level however, due to scalability reasons,
there are 40 or sometimes 96 needles involved operating at once. The
bottle-necks in such set-ups are: 1) Maintaining the aforementioned
variables uniformly for all of the needles and 2) formation of "beads"
in single fibers that we as engineers, want to be of a uniform diameter.
By modifying variables such as the distance to collector, magnitude of
applied voltage, or solution flow rate – researchers can dramatically
change the overall scaffold architecture.
Historically, research on electrospun fibrous scaffolds dates
back to at least the late 1980s when Simon showed that electrospinning
could be used to produced nano- and submicron-scale fibrous scaffolds
from polymer solutions specifically intended for use as in vitro
cell and tissue substrates. This early use of electrospun lattices for
cell culture and tissue engineering showed that various cell types would
adhere to and proliferate upon polycarbonate fibers. It was noted that
as opposed to the flattened morphology typically seen in 2D culture,
cells grown on the electrospun fibers exhibited a more rounded
3-dimensional morphology generally observed of tissues in vivo.
CAD/CAM technologies
Because most of the above techniques are limited when it comes to the control of porosity and pore size, computer assisted design and manufacturing
techniques have been introduced to tissue engineering. First, a
three-dimensional structure is designed using CAD software. The porosity
can be tailored using algorithms within the software. The scaffold is then realized by using ink-jet printing of polymer powders or through Fused Deposition Modeling of a polymer melt.
A 2011 study by El-Ayoubi et al. investigated "3D-plotting technique to produce (biocompatible and biodegradable)
poly-L-Lactide macroporous scaffolds with two different pore sizes" via
solid free-form fabrication (SSF) with computer-aided-design (CAD), to
explore therapeutic articular cartilage replacement as an "alternative to conventional tissue repair".
The study found the smaller the pore size paired with mechanical stress
in a bioreactor (to induce in vivo-like conditions), the higher the
cell viability in potential therapeutic functionality via decreasing
recovery time and increasing transplant effectiveness.
Laser-assisted bioprinting
In a 2012 study,
Koch et al. focused on whether Laser-assisted BioPrinting (LaBP) can be
used to build multicellular 3D patterns in natural matrix, and whether
the generated constructs are functioning and forming tissue. LaBP
arranges small volumes of living cell suspensions in set high-resolution
patterns. The investigation was successful, the researchers foresee that "generated tissue constructs might be used for in vivo testing by implanting them into animal models"
(14). As of this study, only human skin tissue has been synthesized,
though researchers project that "by integrating further cell types (e.g.
melanocytes, Schwann cells, hair follicle cells) into the printed cell construct, the behavior of these cells in a 3D in vitro microenvironment similar to their natural one can be analyzed", which is useful for drug discovery and toxicology studies.
Gustafsson et al.
demonstrated free‐standing, bioactive membranes of cm-sized area, but
only 250 nm thin, that were formed by self‐assembly of spider silk at
the interface of an aqueous solution. The membranes uniquely combine
nanoscale thickness, biodegradability, ultrahigh strain and strength,
permeability to proteins and promote rapid cell adherence and
proliferation. They demonstrated growing a coherent layer of
keratinocytes. These spider silk nanomembranes have also been used to
create a static in-vitro model of a blood vessel.
Assembly methods
A
persistent problem within tissue engineering is mass transport
limitations. Engineered tissues generally lack an initial blood supply,
thus making it difficult for any implanted cells to obtain sufficient
oxygen and nutrients to survive, or function properly.
Self-assembly
Self-assembly
methods have been shown to be promising methods for tissue engineering.
Self-assembly methods have the advantage of allowing tissues to develop
their own extracellular matrix, resulting in tissue that better
recapitulates biochemical and biomechanical properties of native tissue.
Self-assembling engineered articular cartilage was introduced by Jerry
Hu and Kyriacos A. Athanasiou in 2006 and applications of the process have resulted in engineered cartilage approaching the strength of native tissue.
Self-assembly is a prime technology to get cells grown in a lab to
assemble into three-dimensional shapes. To break down tissues into
cells, researchers first have to dissolve the extracellular matrix that
normally binds them together. Once cells are isolated, they must form
the complex structures that make up our natural tissues.
Liquid-based template assembly
The air-liquid surface established by Faraday waves
is explored as a template to assemble biological entities for bottom-up
tissue engineering. This liquid-based template can be dynamically
reconfigured in a few seconds, and the assembly on the template can be
achieved in a scalable and parallel manner. Assembly of microscale
hydrogels, cells, neuron-seeded micro-carrier beads, cell spheroids into
various symmetrical and periodic structures was demonstrated with good
cell viability. Formation of 3-D neural network was achieved after
14-day tissue culture.
It might be possible to print organs, or possibly entire organisms using additive manufacturing
techniques. A recent innovative method of construction uses an ink-jet
mechanism to print precise layers of cells in a matrix of
thermo-reversible gel. Endothelial cells, the cells that line blood
vessels, have been printed in a set of stacked rings. When incubated,
these fused into a tube.
This technique has been referred to as "bioprinting" within the field
as it involves the printing of biological components in a structure
resembling the organ of focus.
The field of three-dimensional and highly accurate models of
biological systems is pioneered by multiple projects and technologies
including a rapid method for creating tissues and even whole organs
involve a 3-D printer that can bio-print the scaffolding and cells layer
by layer into a working tissue sample or organ. The device is presented
in a TED talk by Dr. Anthony Atala, M.D. the Director of the Wake Forest Institute for Regenerative Medicine, and the W.H. Boyce Professor and Chair of the Department of Urology at Wake Forest University, in which a kidney is printed on stage during the seminar and then presented to the crowd.
It is anticipated that this technology will enable the production of
livers in the future for transplantation and theoretically for toxicology and other biological studies as well.
Recently Multi-Photon Processing (MPP) was employed for in vivo
experiments by engineering artificial cartilage constructs. An ex vivo
histological examination showed that certain pore geometry and the
pre-growing of chondrocytes (Cho) prior to implantation significantly
improves the performance of the created 3-D scaffolds. The achieved
biocompatibility was comparable to the commercially available collagen
membranes. The successful outcome of this study supports the idea that
hexagonal-pore-shaped hybrid organic-inorganic micro-structured
scaffolds in combination with Cho seeding may be successfully
implemented for cartilage tissue engineering.
Scaffolding
In 2013, using a 3-D scaffolding of Matrigel in various configurations, substantial pancreatic organoids
was produced in vitro. Clusters of small numbers of cells proliferated
into 40,000 cells within one week. The clusters transform into cells
that make either digestive enzymes or hormones like insulin, self-organizing into branched pancreatic organoids that resemble the pancreas.
The cells are sensitive to the environment, such as gel stiffness
and contact with other cells. Individual cells do not thrive; a minimum
of four proximate cells was required for subsequent organoid
development. Modifications to the medium composition produced either
hollow spheres mainly composed of pancreatic progenitors, or complex
organoids that spontaneously undergo pancreatic morphogenesis and
differentiation. Maintenance and expansion of pancreatic progenitors
require active Notch and FGF signaling, recapitulating in vivo niche signaling interactions.
The organoids were seen as potentially offering mini-organs for drug testing and for spare insulin-producing cells.
Aside from Matrigel 3-D scaffolds, other collagen gel systems
have been developed. Collagen/hyaluronic acid scaffolds have been used
for modeling the mammary gland In Vitro while co-coculturing epithelial
and adipocyte cells. The HyStem kit is another 3-D platform containing
ECM components and hyaluronic acid that has been used for cancer
research. Additionally, hydrogel constituents can be chemically modified
to assist in crosslinking and enhance their mechanical properties.
Tissue culture
In many cases, creation of functional tissues and biological structures in vitro requires extensive culturing
to promote survival, growth and inducement of functionality. In
general, the basic requirements of cells must be maintained in culture,
which include oxygen, pH, humidity, temperature, nutrients and osmotic pressure maintenance.
Tissue engineered cultures also present additional problems in maintaining culture conditions. In standard cell culture, diffusion
is often the sole means of nutrient and metabolite transport. However,
as a culture becomes larger and more complex, such as the case with
engineered organs and whole tissues, other mechanisms must be employed
to maintain the culture, such as the creation of capillary networks
within the tissue.
Another issue with tissue culture is introducing the proper factors
or stimuli required to induce functionality. In many cases, simple
maintenance culture is not sufficient. Growth factors, hormones,
specific metabolites or nutrients, chemical and physical stimuli are
sometimes required. For example, certain cells respond to changes in
oxygen tension as part of their normal development, such as chondrocytes, which must adapt to low oxygen conditions or hypoxia during skeletal development. Others, such as endothelial cells, respond to shear stress from fluid flow, which is encountered in blood vessels.
Mechanical stimuli, such as pressure pulses seem to be beneficial to
all kind of cardiovascular tissue such as heart valves, blood vessels or
pericardium.
In tissue engineering, a bioreactor is a device that attempts to
simulate a physiological environment in order to promote cell or tissue
growth in vitro. A physiological environment can consist of many
different parameters such as temperature, pressure, oxygen or carbon
dioxide concentration, or osmolality of fluid environment, and it can
extend to all kinds of biological, chemical or mechanical stimuli.
Therefore, there are systems that may include the application of forces
such as electromagnetic forces, mechanical pressures, or fluid pressures
to the tissue. These systems can be two- or three-dimensional setups.
Bioreactors can be used in both academic and industry applications.
General-use and application-specific bioreactors are also commercially
available, which may provide static chemical stimulation or a
combination of chemical and mechanical stimulation.
Cell proliferation and differentiation are largely influenced by mechanical and biochemical cues in the surrounding extracellular matrix
environment. Bioreactors are typically developed to replicate the
specific physiological environment of the tissue being grown (e.g., flex
and fluid shearing for heart tissue growth).
This can allow specialized cell lines to thrive in cultures replicating
their native environments, but it also makes bioreactors attractive
tools for culturing stem cells.
A successful stem-cell-based bioreactor is effective at expanding stem
cells with uniform properties and/or promoting controlled, reproducible
differentiation into selected mature cell types.
There are a variety of bioreactors
designed for 3D cell cultures. There are small plastic cylindrical
chambers, as well as glass chambers, with regulated internal humidity
and moisture specifically engineered for the purpose of growing cells in
three dimensions. The bioreactor uses bioactive synthetic materials such as polyethylene terephthalate membranes to surround the spheroid cells in an environment that maintains high levels of nutrients.
They are easy to open and close, so that cell spheroids can be removed
for testing, yet the chamber is able to maintain 100% humidity
throughout.
This humidity is important to achieve maximum cell growth and function.
The bioreactor chamber is part of a larger device that rotates to
ensure equal cell growth in each direction across three dimensions.
QuinXell Technologies now under Quintech Life Sciences from Singapore has developed a bioreactor known as the TisXell Biaxial Bioreactor
which is specially designed for the purpose of tissue engineering. It
is the first bioreactor in the world to have a spherical glass chamber
with biaxial
rotation; specifically to mimic the rotation of the fetus in the womb;
which provides a conducive environment for the growth of tissues.
Multiple forms of mechanical stimulation have also been combined
into a single bioreactor. Using gene expression analysis, one academic
study found that applying a combination of cyclic strain and ultrasound
stimulation to pre-osteoblast cells in a bioreactor accelerated matrix
maturation and differentiation.
The technology of this combined stimulation bioreactor could be used to
grow bone cells more quickly and effectively in future clinical stem
cell therapies.
MC2 Biotek has also developed a bioreactor known as ProtoTissue that uses gas exchange
to maintain high oxygen levels within the cell chamber; improving upon
previous bioreactors, since the higher oxygen levels help the cell grow
and undergo normal cell respiration.
Active areas of research on bioreactors includes increasing
production scale and refining the physiological environment, both of
which could improve the efficiency and efficacy of bioreactors in
research or clinical use. Bioreactors are currently used to study, among
other things, cell and tissue level therapies, cell and tissue response
to specific physiological environment changes, and development of
disease and injury.
Long fiber generation
In 2013, a group from the University of Tokyo developed cell laden fibers up to a meter in length and on the order of 100 µm in size. These fibers were created using a microfluidic device that forms a double coaxial laminar flow. Each 'layer' of the microfluidic device (cells seeded in ECM,
a hydrogel sheath, and finally a calcium chloride solution). The seeded
cells culture within the hydrogel sheath for several days, and then the
sheath is removed with viable cell fibers. Various cell types were
inserted into the ECM core, including myocytes, endothelial cells, nerve cell fibers, and epithelial cell
fibers. This group then showed that these fibers can be woven together
to fabricate tissues or organs in a mechanism similar to textile weaving.
Fibrous morphologies are advantageous in that they provide an
alternative to traditional scaffold design, and many organs (such as
muscle) are composed of fibrous cells.
An artificial organ is an engineered device that can be extra
corporeal or implanted to support impaired or failing organ systems.
Bioartificial organs are typically created with the intent to restore
critical biological functions like in the replacement of diseased hearts
and lungs, or provide drastic quality of life improvements like in the
use of engineered skin on burn victims.
While some examples of bioartificial organs are still in the research
stage of development due to the limitations involved with creating
functional organs, others are currently being used in clinical settings
experimentally and commercially.
Lung
Extracorporeal membrane oxygenation (ECMO) machines, otherwise known as heart and lung machines, are an adaptation of cardiopulmonary bypass techniques that provide heart and lung support.[88]
It is used primarily to support the lungs for a prolonged but still
temporary timeframe (1–30 days) and allow for recovery from reversible
diseases. Robert Bartlett is known as the father of ECMO and performed the first treatment of a newborn using an EMCO machine in 1975.
Skin
Tissue-engineered skin is a type of bioartificial organ that is
often used to treat burns, diabetic foot ulcers, or other large wounds
that cannot heal well on their own. Artificial skin can be made from
autografts, allografts, and xenografts. Autografted skin comes from a
patient's own skin, which allows the dermis to have a faster healing
rate, and the donor site can be re-harvested a few times. Allograft skin
often comes from cadaver skin and is mostly used to treat burn victims.
Lastly, xenografted skin comes from animals and provides a temporary
healing structure for the skin. They assist in dermal regeneration, but
cannot become part of the host skin.
Tissue-engineered skin is now available in commercial products.
Integra, originally used to only treat burns, consists of a collagen
matrix and chondroitin sulfate that can be used as a skin replacement.
The chondroitin sulfate functions as a component of proteoglycans, which
helps to form the extracellular matrix.
Integra can be repopulated and revascularized while maintaining its
dermal collagen architecture, making it a bioartificial organ.
Dermagraft, another commercial-made tissue-engineered skin product, is
made out of living fibroblasts. These fibroblasts proliferate and
produce growth factors, collagen, and ECM proteins, that help build
granulation tissue.
Heart
Since the
number of patients awaiting a heart transplant is continuously
increasing over time, and the number of patients on the waiting list
surpasses the organ availability,
artificial organs used as replacement therapy for terminal heart
failure would help alleviate this difficulty. Artificial hearts are
usually used to bridge the heart transplantation or can be applied as
replacement therapy for terminal heart malfunction. The total artificial heart (TAH), first introduced by Dr. Vladimir P. Demikhov in 1937,
emerged as an ideal alternative. Since then it has been developed and
improved as a mechanical pump that provides long-term circulatory
support and replaces diseased or damaged heart ventricles that cannot
properly pump the blood, restoring thus the pulmonary and systemic flow.
Some of the current TAHs include AbioCor, an FDA-approved device that
comprises two artificial ventricles and their valves, and does not
require subcutaneous connections, and is indicated for patients with
biventricular heart failure. In 2010 SynCardia released the portable
freedom driver that allows patients to have a portable device without
being confined to the hospital.
Kidney
While kidney transplants are possible, renal failure is more often treated using an artificial kidney.
The first artificial kidneys and the majority of those currently in use
are extracorporeal, such as with hemodialysis, which filters blood
directly, or peritoneal dialysis, which filters via a fluid in the
abdomen.
In order to contribute to the biological functions of a kidney such as
producing metabolic factors or hormones, some artificial kidneys
incorporate renal cells. There has been progress in the way of making these devices smaller and more transportable, or even implantable .
One challenge still to be faced in these smaller devices is countering
the limited volume and therefore limited filtering capabilities.
Bioscaffolds have also been introduced to provide a framework
upon which normal kidney tissue can be regenerated. These scaffolds
encompass natural scaffolds (e.g., decellularized kidneys, collagen hydrogel, or silk fibroin), synthetic scaffolds (e.g., poly[lactic-co-glycolic acid]
or other polymers), or a combination of two or more natural and
synthetic scaffolds. These scaffolds can be implanted into the body
either without cell treatment or after a period of stem cell seeding and
incubation. In vitro and In vivo studies are being conducted to
compare and optimize the type of scaffold and to assess whether cell
seeding prior to implantation adds to the viability, regeneration and
effective function of the kidneys. A recent systematic review and
meta-analysis compared the results of published animal studies and
identified that improved outcomes are reported with the use of hybrid
(mixed) scaffolds and cell seeding;
however, the meta-analysis of these results were not in agreement with
the evaluation of descriptive results from the review. Therefore,
further studies involving larger animals and novel scaffolds, and more
transparent reproduction of previous studies are advisable.
Biomimetics is a field that aims to produce materials and systems that replicate those present in nature.
In the context of tissue engineering, this is a common approach used by
engineers to create materials for these applications that are
comparable to native tissues in terms of their structure, properties,
and biocompatibility. Material properties are largely dependent on
physical, structural, and chemical characteristics of that material.
Subsequently, a biomimetic approach to system design will become
significant in material integration, and a sufficient understanding of
biological processes and interactions will be necessary. Replication of
biological systems and processes may also be used in the synthesis of
bio-inspired materials to achieve conditions that produce the desired
biological material. Therefore, if a material is synthesized having the
same characteristics of biological tissues both structurally and
chemically, then ideally the synthesized material will have similar
properties. This technique has an extensive history originating from the
idea of using natural phenomenon as design inspiration for solutions to
human problems. Many modern advancements in technology have been
inspired by nature and natural systems, including aircraft, automobiles,
architecture, and even industrial systems. Advancements in
nanotechnology initiated the application of this technique to micro- and
nano-scale
problems, including tissue engineering. This technique has been used to
develop synthetic bone tissues, vascular technologies, scaffolding
materials and integration techniques, and functionalized nanoparticles.
Constructing neural networks in soft material
In
2018, scientists at Brandeis University reported their research on soft
material embedded with chemical networks which can mimic the smooth and
coordinated behavior of neural tissue. This research was funded by the U.S. Army Research Laboratory. The researchers presented an experimental system of neural networks, theoretically modeled as reaction-diffusion systems. Within the networks was an array of patterned reactors, each performing the Belousov-Zhabotinsky (BZ) reaction. These reactors could function on a nanoliter scale.
The researchers state that the inspiration for their project was the movement of the blue ribbon eel. The eel's movements are controlled by electrical impulses determined by a class of neural networks called the central pattern generator. Central Pattern Generators function within the autonomic nervous system to control bodily functions such as respiration, movement, and peristalsis.
Qualities of the reactor that were designed were the network topology, boundary conditions,
initial conditions, reactor volume, coupling strength, and the synaptic
polarity of the reactor (whether its behavior is inhibitory or
excitatory). A BZ emulsion system with a solid elastomerpolydimethylsiloxane
(PDMS) was designed. Both light and bromine permeable PDMS have been
reported as viable methods to create a pacemaker for neural networks.
Market
The
history of the tissue engineering market can be divided into three major
parts. The time before the crash of the biotech market in the early
2000s, the crash and the time afterward.
Beginning
Most
early progress in tissue engineering research was done in the US. This
is due to less strict regulations regarding stem cell research and more
available funding than in other countries. This leads to the creation of
academic startups many of them coming from Harvard or MIT. Examples are BioHybrid Technologies whose founder, Bill Chick, went to Harvard Medical School
and focused on the creation of artificial pancreas. Another example
would be Organogenesis Inc. whose founder went to MIT and worked on skin
engineering products. Other companies with links to the MIT are TEI
Biosciences, Therics and Guilford Pharmaceuticals.
The renewed interest in biotechnologies in the 1980s leads to many
private investors investing in these new technologies even though the
business models of these early startups were often not very clear and
did not present a path to long term profitability. Government sponsors were more restrained in their funding as tissue engineering was considered a high-risk investment.
In the UK the market got off to a slower start even though the regulations on stem cell
research were not strict as well. This is mainly due to more investors
being less willing to invest in these new technologies which were
considered to be high-risk investments. Another problem faced by British companies was getting the NHS
to pay for their products. This especially because the NHS runs a
cost-effectiveness analysis on all supported products. Novel
technologies often do not do well in this respect.
In Japan, the regulatory situation was quite different. First
cell cultivation was only allowed in a hospital setting and second
academic scientists employed by state-owned universities were not
allowed outside employment until 1998. Moreover, the Japanese
authorities took longer to approve new drugs and treatments than there
US and European counterparts.
For these reasons in the early days of the Japanese market, the
focus was mainly on getting products that were already approved
elsewhere in Japan and selling them. Contrary to the US market the early
actors in Japan were mainly big firms or sub-companies of such big
firms, such as J-TEC, Menicon and Terumo, and not small startups.
After regulatory changes in 2014, which allowed cell cultivation
outside of a hospital setting, the speed of research in Japan increased
and Japanese companies also started to develop their own products.
Crash
Soon after the big boom, the first problems started to appear. There were problems getting products approved by the FDA
and if they got approved there were often difficulties in getting
insurance providers to pay for the products and getting it accepted by
health care providers.
For example, organogenesis ran into problems marketing its
product and integrating its product in the health system. This partially
due to the difficulties of handling living cells and the increased
difficulties faced by physicians in using these products over
conventional methods.
Another example would be Advanced Tissue Sciences Dermagraft skin
product which could not create a high enough demand without
reimbursements from insurance providers. Reasons for this were $4000
price-tag and the circumstance that Additionally Advanced Tissue
Sciences struggled to get their product known by physicians.
The above examples demonstrate how companies struggled to make
profit. This, in turn, lead investors to lose patience and stopping
further funding. In consequence, several Tissue Engineering companies
such as Organogenesis and Advanced Tissue Sciences filed for bankruptcy
in the early 2000s. At this time, these were the only ones having
commercial skin products on the market.
Reemergence
The
technologies of the bankrupt or struggling companies were often bought
by other companies which continued the development under more
conservative business models. Examples of companies who sold their products after folding were Curis and Intercytex.
Many of the companies abandoned their long-term goals of
developing fully functional organs in favor of products and technologies
that could turn a profit in the short run. Examples of these kinds of products are products in the cosmetic and testing industry.
In other cases such as in the case of Advanced Tissue Sciences, the founders started new companies.
In the 2010s the regulatory framework also started to facilitate
faster time to market especially in the US as new centres and pathways
were created by the FDA specifically aimed at products coming from
living cells such as the Center for Biologics Evaluation and Research.
The first tissue engineering products started to get commercially profitable in the 2010s.
Regulation
In Europe, regulation is currently split into three areas of regulation: medical devices, medicinal products, and biologics.
Tissue engineering products are often of hybrid nature, as they are
often composed of cells and a supporting structure. While some products
can be approved as medicinal products, others need to gain approval as
medical devices.
Derksen explains in her thesis that tissue engineering researchers are
sometimes confronted with regulation that does not fit the
characteristics of tissue engineering.
New regulatory regimes have been observed in Europe that tackle these issues. An explanation for the difficulties in finding regulatory consensus in this matter is given by a survey conducted in the UK. The authors attribute these problems to the close relatedness and overlap with other technologies such as xenotransplantation. It can therefore not be handled separately by regulatory bodies. Regulation is further complicated by the ethical controversies associated with this and related fields of research (e.g. stem cells controversy, ethics of organ transplantation). The same survey as mentioned above
shows on the example of autologous cartilage transplantation that a
specific technology can be regarded as 'pure' or 'polluted' by the same
social actor.
Two regulatory movements are most relevant to tissue engineering in the European Union. These are Directive 2004/23/EC on standards of quality and safety for the sourcing and processing of human tissues
which was adopted by the European Parliament in 2004 and a proposed
Human Tissue-Engineered Products regulation. The latter was developed
under the auspices of the European Commission DG Enterprise and
presented in Brussels in 2004.