The contraction of cardiac muscle (heart muscle) in all animals is initiated by electrical impulses known as action potentials. The rate at which these impulses fire, controls the rate of cardiac contraction, that is, the heart rate. The cells that create these rhythmic impulses, setting the pace for blood pumping, are called pacemaker cells, and they directly control the heart rate. They make up the cardiac pacemaker, that is, the natural pacemaker of the heart. In most humans, the concentration of pacemaker cells in the sinoatrial (SA) node is the natural pacemaker, and the resultant rhythm is a sinus rhythm.
Sometimes an ectopic pacemaker sets the pace, if the SA node is damaged or if the electrical conduction system of the heart has problems. Cardiac arrhythmias can cause heart block, in which the contractions lose any useful rhythm. In humans, and occasionally in animals, a mechanical device called an artificial pacemaker
(or simply "pacemaker") may be used after damage to the body's
intrinsic conduction system to produce these impulses synthetically.
Control
Primary (SA node)
One percent of the cardiomyocytes in the myocardium possess the ability to generate electrical impulses (or action potentials) spontaneously.
A specialized portion of the heart, called the sinoatrial node (SA node), is responsible for atrial propagation of this potential.
The sinoatrial node (SA node) is a group of cells positioned on the wall of the right atrium, near the entrance of the superior vena cava. These cells are modified cardiomyocytes. They possess rudimentary contractile filaments, but contract relatively weakly compared to the cardiac contractile cells.
The pacemaker cells are connected to neighboring contractile cells via gap junctions,
which enable them to locally depolarize adjacent cells. Gap junctions
allow the passage of positive cations from the depolarization of the
pacemaker cell to adjacent contractile cells. This starts the
depolarization and eventual action potential in contractile cells.
Having cardiomyocytes connected via gap junctions allow all contractile
cells of the heart to act in a coordinated fashion and contract as a
unit. All the while being in sync with the pacemaker cells; this is the
property that allows the pacemaker cells to control contraction in all
other cardiomyocytes.
Cells in the SA node spontaneously depolarize,
ultimately resulting in contraction, approximately 100 times per
minute. This native rate is constantly modified by the activity of sympathetic and parasympathetic nerve fibers via the autonomic nervous system,
so that the average resting cardiac rate in adult humans is about 70
beats per minute. Because the sinoatrial node is responsible for the
rest of the heart's electrical activity, it is sometimes called the primary pacemaker.
Secondary (AV junction and Bundle of His)
If
the SA node does not function properly and is unable to control the
heart rate, a group of cells further down the heart will become the ectopic pacemaker of the heart. These cells form the Atrioventricular node (or AV node),
which is an area between the left atrium and the right ventricle within
the atrial septum, will take over the pacemaker responsibility.
The cells of the AV node normally discharge at about 40-60 beats per minute, and are called the secondary pacemaker.
Further down the electrical conducting system of the heart is the Bundle of His. The left and right branches of this bundle, and the Purkinje fibers,
will also produce a spontaneous action potential at a rate of 30-40
beats per minute, so if the SA and AV node both fail to function, these
cells can become pacemakers. It is important to realize that these cells
will be initiating action potentials and contraction at a much lower
rate than the primary or secondary pacemaker cells.
The SA node controls the rate of contraction for the entire heart
muscle because its cells have the quickest rate of spontaneous
depolarization, thus they initiate action potentials the quickest. The
action potential generated by the SA node passes down the electrical conduction system of the heart,
and depolarizes the other potential pacemaker cells (AV node) to
initiate action potentials before these other cells have had a chance to
generate their own spontaneous action potential, thus they contract and
propagate electrical impulses to the pace set by the cells of the SA
node. This is the normal conduction of electrical activity in the heart.
Generation of action potentials
There
are 3 main stages in the generation of an action potential in a
pacemaker cell. Since the stages are analogous to contraction of cardiac muscle cells, they have the same naming system. This can lead to some confusion. There is no phase 1 or 2, just phases 0, 3, and 4.
Phase 4 - Pacemaker potential
The key to the rhythmic firing of pacemaker cells is that, unlike other neurons
in the body, these cells will slowly depolarize by themselves and do
not need any outside innervation from the autonomic nervous system to
fire action potentials.
As in all other cells, the resting potential of a pacemaker cell (-60mV to -70mV) is caused by a continuous outflow or "leak" of potassium ions through ion channel proteins in the membrane
that surrounds the cells. However, in pacemaker cells, this potassium
permeability (efflux) decreases as time goes on, causing a slow
depolarization. In addition, there is a slow, continuous inward flow of sodium, called the "funny" or pacemaker current.
These two relative ion concentration changes slowly depolarize (make
more positive) the inside membrane potential (voltage) of the cell,
giving these cells their pacemaker potential. When the membrane
potential gets depolarized to about -40mV it has reached threshold
(cells enter phase 0), allowing an action potential to be generated.
Phase 0 - Upstroke
Though much faster than the depolarization of phase 4, the upstroke in a pacemaker cell is slow compared to that in an axon.
The SA and AV node do not have fast sodium channels like neurons,
and the depolarization is mainly caused by a slow influx of calcium
ions. (The funny current also increases). Calcium enters the cell via
voltage-sensitive calcium channels that open when the threshold is
reached. This calcium influx produces the rising phase of the action
potential, which results in the reversal of membrane potential to a peak
of about +10mV. It is important to note that intracellular calcium
causes muscular contraction in contractile cells, and is the effector
ion. In heart pacemaker cells, phase 0 depends on the activation of L-type calcium channels
instead of the activation of voltage-gated fast sodium channels, which
are responsible for initiating action potentials in contractile
(non-pacemaker) cells. For this reason, the pacemaker action potential
rising phase slope is more gradual than that of the contractile cell
(image 2).
Phase 3 - Repolarization
The
reversal of membrane potential triggers the opening of potassium leak
channels, resulting in the rapid loss of potassium ions from the inside
of the cell, causing repolarization (Vm gets more negative).
The calcium channels are also inactivated soon after they open. In
addition, as sodium channels become inactivated, sodium permeability
into the cell is decreased. These ion concentration changes slowly
repolarize the cell to resting membrane potential (-60mV). Another
important note at this phase is that ionic pumps restore ion
concentrations to pre-action potential status. The sodium-calcium exchanger ionic pump works to pump calcium out of the intracellular space, thus effectively relaxing the cell. The sodium/potassium pump
restores ion concentrations of sodium and potassium ions by pumping
sodium out of the cell and pumping (exchanging) potassium into the cell.
Restoring these ion concentrations is vital because it enables the cell
to reset itself and enables it to repeat the process of spontaneous
depolarization leading to activation of an action potential.
Clinical significance
Damage to the SA node
If the SA node does not function, or the impulse generated in the SA node is blocked before it travels down the electrical conduction system, a group of cells further down the heart will become its pacemaker. This center is typically represented by cells inside the atrioventricular node (AV node), which is an area between the atria and ventricles, within the atrial septum. If the AV node also fails, Purkinje fibers
are occasionally capable of acting as the default or "escape"
pacemaker. The reason Purkinje cells do not normally control the heart
rate is that they generate action potentials at a lower frequency than
the AV or SA nodes.