Search This Blog

Sunday, January 6, 2019

Microgrid

From Wikipedia, the free encyclopedia

A microgrid is a localized group of electricity sources and loads that normally operates connected to and synchronous with the traditional wide area synchronous grid (macrogrid), but can also disconnect to "island mode" — and function autonomously as physical or economic conditions dictate. 
 
In this way, a microgrid can effectively integrate various sources of distributed generation (DG), especially Renewable Energy Sources (RES) - renewable electricity, and can supply emergency power, changing between island and connected modes.

Control and protection are challenges to microgrids. A very important feature is also to provide multiple end-use needs as heating, cooling, and electricity at the same time since this allows energy carrier substitution and increased energy efficiency due to waste heat utilization for heating, domestic hot water, and cooling purposes (cross sectoral energy usage).

Definition


The United States Department of Energy Microgrid Exchange Group defines a microgrid as a group of interconnected loads and distributed energy resources (DERs) within clearly defined electrical boundaries that acts as a single controllable entity with respect to the grid. A microgrid can connect and disconnect from the grid to enable it to operate in both connected or island-mode. 

The EU research project describes a microgrid as comprising Low-Voltage (LV) distribution systems with distributed energy resources (DERs) (microturbines, fuel cells, photovoltaics (PV), etc.), storage devices (batteries, flywheels) energy storage system and flexible loads. Such systems can operate either connected or disconnected from the main grid. The operation of microsources in the network can provide benefits to the overall system performance, if managed and coordinated efficiently.

Types of microgrids

A typical scheme of an electric based microgrid with renewable energy resources in grid-connected mode

Campus Environment/Institutional Microgrids

The focus of campus microgrids is aggregating existing on-site generation with multiple loads that located in tight geography in which owner easily manage them.

Community Microgrids

Community Microgrids can serve a few up to thousands of customers and support the penetration of local energy (electricity, heating, and cooling). In a community microgrid, some houses may have some renewable sources that can supply their demand as well as that of their neighbors within the same community. The community microgrid may also have a centralized or several distributed energy storages. Such microgrids can be in the form of an ac and dc microgrid coupled together through a bi-directional power electronic converter.

Remote Off-grid Microgrids

These microgrids never connect to the Macrogrid and instead operate in an island mode at all times because of economic issues or geographical position. Typically, an "off-grid" microgrid is built in areas that are far distant from any transmission and distribution infrastructure and, therefore, have no connection to the utility grid. Studies have demonstrated that operating a remote area or islands' off-grid microgrids, that are dominated by renewable sources, will reduce the levelized cost of electricity production over the life of such microgrid projects.

Large remote areas may be supplied by several independent microgrids, each with a different owner (operator). Although such microgrids are traditionally designed to be energy self-sufficient, intermittent renewable sources and their unexpected and sharp variations can cause unexpected power shortfall or excessive generation in those microgrids. This will immediately cause unacceptable voltage or frequency deviation in the microgrids. To remedy such situations, it is possible to interconnect such microgrids provisionally to a suitable neighboring microgrid to exchange power and improve the voltage and frequency deviations. This can be achieved through a power electronics-based switch after a proper synchronization or a back to back connection of two power electronic converters and after confirming the stability of the new system. The determination of a need to interconnect neighboring microgrids and finding the suitable microgrid to couple with can be achieved through optimization or decision making approaches.

Military Base Microgrids

These microgrids are being actively deployed with focus on both physical and cyber security for military facilities in order to assure reliable power without relying on the Macrogrid.

Commercial and Industrial (C&I) Microgrids

These types of microgrids are maturing quickly in North America and Asia Pacific; however, the lack of well –known standards for these types of microgrids limits them globally. Main reasons for the installation of an industrial microgrid are power supply security and its reliability. There are many manufacturing processes in which an interruption of the power supply may cause high revenue losses and long start-up time. Industrial microgrids can be designed to supply circular-economy (near-)zero-emission industrial processes, and can integrate combined heat and power (CHP) generation, being fed by both renewable sources and waste processing; energy storage can be additionally used to optimize the operations of these sub-systems. 

Basic components in microgrids

The Solar Settlement, a sustainable housing community project in Freiburg, Germany.

Local generation

A microgrid presents various types of generation sources that feed electricity, heating, and cooling to user. These sources are divided into two major groups – thermal energy sources (e.g,. natural gas or biogas generators or micro combined heat and power) and renewable generation sources (e.g. wind turbines, solar).

Consumption

In a microgrid, consumption simply refers to elements that consume electricity, heat, and cooling which range from single devices to lighting, heating system of buildings, commercial centers, etc. In the case of controllable loads, the electricity consumption can be modified in demand of the network.

Energy Storage

In microgrid, energy storage is able to perform multiple functions, such as ensuring power quality, including frequency and voltage regulation, smoothing the output of renewable energy sources, providing backup power for the system and playing crucial role in cost optimization. It includes all of electrical, pressure, gravitational, flywheel, and heat storage technologies. When multiple energy storages with various capacities are available in a microgrid, it is preferred to coordinate their charging and discharging such that a smaller energy storage does not discharge faster than those with larger capacities. Likewise, it is preferred a smaller one does not get fully charged before those with larger capacities. This can be achieved under a coordinated control of energy storage based on their state of charge. If multiple energy storage systems (possibly working on different technologies) are used and they are controlled by a unique supervising unit (an Energy Management System - EMS), a hierarchical control based on a master/slaves architecture can ensure best operations, particularly in the islanded mode. 

Point of common coupling (PCC)

It is the point in the electric circuit where a microgrid is connected to a main grid. Microgrids that do not have a PCC are called isolated microgrids which are usually presented in the case of remote sites (e.g., remote communities or remote industrial sites) where an interconnection with the main grid is not feasible due to either technical or economic constraints.

Advantages and challenges of microgrids

Advantages

A microgrid is capable of operating in grid-connected and stand-alone modes and of handling the transition between the two. In the grid-connected mode, ancillary services can be provided by trading activity between the microgrid and the main grid. Other possible revenue streams exist. In the islanded mode, the real and reactive power generated within the microgrid, including that provided by the energy storage system, should be in balance with the demand of local loads.

A microgrid may transition between these two modes because of scheduled maintenance, degraded power quality or a shortage in the host grid, faults in the local grid, or for economical reasons. By means of modifying energy flow through microgrid components, microgrids facilitate the integration of renewable energy generation such as photovoltaic, wind and fuel cell generations without requiring re-design of the national distribution system. Modern optimization methods can also be incorporated into the microgrid energy management system to improve efficiency, economics, and resiliency.

Challenges

Microgrids, and integration of DER units in general, introduce a number of operational challenges that need to be addressed in the design of control and protection systems in order to ensure that the present levels of reliability are not significantly affected and the potential benefits of Distributed Generation (DG) units are fully harnessed. Some of these challenges arise from invalid assumptions typically applied to conventional distribution systems, while others are the result of stability issues formerly observed only at a transmission system level. The most relevant challenges in microgrid protection and control include:
  • Bidirectional power flows: The presence of distributed generation (DG) units in the network at low voltage levels can cause reverse power flows that may lead to complications in protection coordination, undesirable power flow patterns, fault current distribution, and voltage control.
  • Stability issues: Interaction of control system of DG units may create local oscillations, requiring a thorough small-disturbance stability analysis. Moreover, transition activities between the grid-connected and islanding (stand-alone) modes of operation in a microgrid can create transient stability. Recent studies have shown that direct-current (DC) microgrid interface can result in significantly simpler control structure, more energy efficient distribution and higher current carrying capacity for the same line ratings.
  • Modeling: Many characteristic in traditional scheme such as prevalence of three-phase balanced conditions, primarily inductive transmission lines, and constant-power loads are not necessarily hold valid for microgrids, and consequently models need to be revised.
  • Low inertia: The microgrid shows low-inertia characteristic that are different to bulk power systems where high number of synchronous generators ensures a relatively large inertia. Especially if there is a significant share of power electronic-interfaced DG units, this phenomenon is more clear. The low inertia in the system can lead to severe frequency deviations in stand-alone operation if a proper control mechanism is not implemented.
  • Uncertainty: The operation of microgrids contain very much uncertainty in which the economical and reliable operation of microgrids rely on. Load profile and weather forecast are two of them that make this coordination becomes more challenging in isolated microgrids, where the critical demand-supply balance and typically higher component failure rates require solving a strongly coupled problem over an extended horizon. This uncertainty is higher than those in bulk power systems, due to the reduced number of loads and highly correlated variations of available energy resources (limited averaging effect).

Modelling Tools

To plan and install Microgrids correctly, engineering modelling is needed. Multiple simulation tools and optimization tools exist to model the economic and electric effects of Microgrids. A widely used economic optimization tool is the Distributed Energy Resources Customer Adoption Model (DER-CAM) from Lawrence Berkeley National Laboratory. Another frequently used commercial economic modelling tool is Homer Energy, originally designed by the National Renewable Energy Laboratory. There are also some power flow and electrical design tools guiding the Microgrid developers. The Pacific Northwest National Laboratory designed the public available GridLAB-D tool and the Electric Power Research Institute (EPRI) designed OpenDSS to simulate the distribution system (for Microgrids). A professional integrated DER-CAM and OpenDSS version is available via BankableEnergy. A European tool that can be used for electrical, cooling, heating, and process heat demand simulation is EnergyPLAN from the Aalborg University in Denmark.

Microgrid control

Hierarchical Control
 
In regards to the architecture of microgrid control, or any control problem, there are two different approaches that can be identified: centralized and decentralized. A fully centralized control relies on a large amount of information transmittance between involving units and then the decision is made at a single point. Hence, it will present a big problem in implementation since interconnected power systems usually cover extended geographic locations and involves an enormous number of units. On the other hand, in a fully decentralized control, each unit is controlled by its local controller without knowing the situation of others. A compromise between those two extreme control schemes can be achieved by means of a hierarchical control scheme consisting of three control levels: primary, secondary, and tertiary.

Primary control

The primary control is designed to satisfy the following requirements:
  • To stabilize the voltage and frequency
  • To offer plug and play capability for DERs and properly share the active and reactive power among them, preferably, without any communication links
  • To mitigate circulating currents that can cause over-current phenomenon in the power electronic devices
The primary control provides the setpoints for a lower controller which are the voltage and current control loops of DERs. These inner control loops are commonly referred to as zero-level control.

Secondary control

Secondary control has typically seconds to minutes sampling time (i.e. slower than the previous one) which justifies the decoupled dynamics of the primary and the secondary control loops and facilitates their individual designs. Setpoint of primary control is given by secondary control in which as a centralized controller, it restores the microgrid voltage and frequency and compensates for the deviations caused by variations of loads or renewable sources. The secondary control can also be designed to satisfy the power quality requirements, e.g., voltage balancing at critical buses.

Tertiary control

Tertiary control is the last (and the slowest) control level which consider economical concerns in the optimal operation of the microgrid (sampling time is from minutes to hours), and manages the power flow between microgrid and main grid. This level often involves the prediction of weather, grid tariff, and loads in the next hours or day to design a generator dispatch plan that achieves economic savings. In case of emergency like blackouts, Tertiary control could be utilized to manage a group of interconnected microgrids to form what is called "microgrid clustering" that could act as a virtual power plant and keep supplying at least the critical loads. During this situation the central controller should select one of the microgrid to be the slack (i.e. master) and the rest as PV and load buses according to a predefined algorithm and the existing conditions of the system (i.e. Demand and generation), in this case, the control should be real time or at least high sampling rate.

IEEE 2030.7

A less utility influenced controller framework has been designed in the latest Microgrid controller standard from the Institute of Electrical and Electronics Engineers, the IEEE 2030.7. That concept relies on 4 blocks: a) Device Level control (e.g. Voltage and Frequency Control), b) Local Area Control (e.g. data communication), c) Supervisory (software) controller (e.g. forward looking dispatch optimization of generation and load resources), and d) Grid Layer (e.g. communication with utility).

Elementary control

A wide variety of complex control algorithms exist, making it difficult for small Microgrids and residential Distributed Energy Resource (DER) users to implement energy management and control systems. Especially, communication upgrades and data information systems can make it expensive. Thus, some projects try to simplify the control via off-the shelf products and make it usable for the mainstream (e.g. using a Raspberry Pi).

Examples

Les Anglais, Haiti

A wirelessly managed microgrid is deployed in rural Les Anglais, Haiti. The system consists of a three-tiered architecture with a cloud-based monitoring and control service, a local embedded gateway infrastructure and a mesh network of wireless smart meters deployed at 52 buildings. 

Non-Technical Loss (NTL) represents a major challenge when providing reliable electrical service in developing countries, where it often accounts for 11-15% of total generation capacity. An extensive data-driven simulation on 72 days of wireless meter data from a 430-home microgrid deployed in Les Anglais, Haiti has been conducted to investigate how to distinguish NTL from the total power losses which helps energy theft detection.

Mpeketoni, Kenya

A community-based diesel-powered micro-grid system was set up in rural Kenya near Mpeketoni called the Mpeketoni Electricity Project. Due to the installment of these microgrids Mpeketoni has seen a large growth in its infrastructure. Such growth includes increased productivity per worker with an increase of 100% to 200% and an income levels increase of 20–70% depending on the product.

Stone Edge Farm Winery

A micro-turbine, fuel-cell, multiple batteries, hydrogen electrolyzer, and PV enabled Winery in Sonoma, California.

Microgeneration

From Wikipedia, the free encyclopedia

A group of small-scale wind turbines providing electricity to a community in Dali, Yunnan, China
 
Microgeneration is the small-scale generation of heat and electric power by individuals, small businesses and communities to meet their own needs, as alternatives or supplements to traditional centralized grid-connected power. Although this may be motivated by practical considerations, such as unreliable grid power or long distance from the electrical grid, the term is mainly used currently for environmentally conscious approaches that aspire to zero or low-carbon footprints or cost reduction. It differs from micropower in that it is principally concerned with fixed power plants rather than for use with mobile devices.

Technologies and set-up

Microgeneration technologies include small-scale wind turbines, micro hydro, solar PV systems, microbial fuel cells, ground source heat pumps, and micro combined heat and power installations. These technologies are often combined to form a hybrid power solution that can offer superior performance and lower cost than a system based on one generator.

Power plant

In addition to the electricity production plant (e.g. wind turbine and solar panel), infrastructure for energy storage and power conversion and a hook-up to the regular electricity grid is usually needed and/or foreseen. Although a hookup to the regular electricity grid is not essential, it helps to decrease costs by allowing financial recompensation schemes. In the developing world however, the start-up cost for this equipment is generally too high, thus leaving no choice but to opt for alternative set-ups.

Extra equipment needed besides the power plant

A complete PV-solar system
 
The whole of the equipment required to set up a working system and for an off-the-grid generation and/or a hook up to the electricity grid herefore is termed a balance of system and is composed of the following parts with PV-systems:

Energy storage apparatus

A major issue with off-grid solar and wind systems is that the power is often needed when the sun is not shining or when the wind is calm, this is generally not required for purely grid-connected systems:
or other means of energy storage (e.g. hydrogen fuel cells, Flywheel energy storage, pumped-storage hydroelectricity, compressed air tanks, ...)
For converting DC battery power into AC as required for many appliances, or for feeding excess power into a commercial power grid

Safety equipment

Usually, in microgeneration for homes in the developing world, prefabricated house-wiring systems (as wiring harnesses or prefabricated distribution units) are used instead . Simplified house-wiring boxes and cables, known as wiring harnesses, can simply be bought and mounted into the building without requiring much knowledge about the wiring itself. As such, even people without technical expertise are able to install them. In addition, they are also comparatively cheap and offer safety advantages.
Small-scale (DIY) generation system

Wind turbine specific

With wind turbines, hydroelectric plants, ... the extra equipment needed is more or less the same as with PV-systems (depending on the type of wind turbine used, yet also include:
  • a manual disconnect switch
  • foundation for the tower
  • grounding system
  • shutoff and/or dummy-load devices for use in high wind when power generated exceeds current needs and storage system capacity.
Vibro-wind power
A new wind energy technology is being developed that converts energy from wind energy vibrations to electricity. This energy, called Vibro-Wind technology, can use winds of less strength than normal wind turbines, and can be placed in almost any location.

A prototype consisted of a panel mounted with oscillators made out of pieces of foam. The conversion from mechanical to electrical energy is done using a piezoelectric transducer, a device made of a ceramic or polymer that emits electrons when stressed. The building of this prototype was led by Francis Moon, professor of mechanical and aerospace engineering at Cornell University. Moon's work in Vibro-Wind Technology was funded by the Atkinson Center for a Sustainable Future at Cornell.

Possible set-ups

Several microgeneration set-ups are possible. These are:
  • Off-the-grid set-ups which include:
    • Off-the grid set-ups without energy storage (e.g., battery, ...)
    • Off-the grid set-ups with energy storage (e.g., battery, ...)
    • Battery charging stations 
  • Grid-connected set-ups which include:
    • Grid connected with backup to power critical loads
    • Grid-connected set-ups without financial recompensation scheme
    • Grid-connected set-ups with net metering
    • Grid connected set-ups with net purchase and sale 
All set-ups mentioned can work either on a single power plant or a combination of power plants (in which case it is called a hybrid power system). For safety, grid-connected set-ups must automatically switch off or enter an "anti-islanding mode" when there is a failure of the mains power supply.

Costs

Depending on the set-up chosen (financial recompensation scheme, power plant, extra equipment), prices may vary. According to Practical Action, microgeneration at home which uses the latest in cost saving-technology (wiring harnesses, ready boards, cheap DIY-power plants, e.g. DIY wind turbines) the household expenditure can be extremely low-cost. In fact, Practical Action mentions that many households in farming communities in the developing world spend less than $1 for electricity per month. However, if matters are handled less economically (using more commercial systems/approaches), costs will be dramatically higher. In most cases however, financial advantage will still be done using microgeneration on renewable power plants; often in the range of 50-90%  as local production has no electricity transportation losses on long distance power lines or energy losses from the Joule effect in transformers where in general 8-15% of the energy is lost.

In the UK, the government offers both grants and feedback payments to help businesses, communities and private homes to install these technologies. Businesses can write the full cost of installation off against taxable profits whilst homeowners receive a flat rate grant or payments per kWh of electricity generated and paid back into the national grid. Community organisations can also receive up to £200,000 in grant funding.

In the UK, the Microgeneration Certification Scheme provides approval for Microgeneration Installers and Products which is a mandatory requirement of funding schemes such as the Feed in Tariffs and Renewable Heat Incentive.

Grid parity

Grid parity (or socket parity) occurs when an alternative energy source can generate electricity at a levelized cost (LCoE) that is less than or equal to the price of purchasing power from the electricity grid. Reaching grid parity is considered to be the point at which an energy source becomes a contender for widespread development without subsidies or government support. It is widely believed that a wholesale shift in generation to these forms of energy will take place when they reach grid parity. 

Grid parity has been reached in some locations with on-shore wind power around 2000, and with solar power it was achieved for the first time in Spain in 2013.

Comparison with large-scale generation


microgeneration large-scale generation
Other names Distributed generation Centralized generation
Waste Heat by-product Can be used for heating purposes, thus greatly increasing efficiency and offsetting energy total costs. This method is known as micro combined heat and power (microCHP).
It is used in some privately owned industrial combined heat and power (CHP) installations. It's also use in large-scale applications where it's called district heating and uses the heat that is normally exhausted by inefficient powerplants.
Transmission losses Proximity to end user typically closer resulting in potentially fewer losses. A significant proportion of electrical power is lost during transmission (approximately 8% in the United Kingdom according to BBC Radio 4 Today programme in March 2006).
Changes to Grid reduces the transmission load, and thus reduces the need for grid upgrades increases the power transmitted, and thus increases the need for grid upgrades
Grid failure event Electricity may still be available to local area in many circumstances Electricity may be not available due to grid
Consumer choices May choose to purchase any legal system May choose to purchase offerings of the power company
Reliability and Maintenance requirements photovoltaics, Stirling engines, and certain other systems, are usually extremely reliable, and can generate electric power continuously for many thousands of hours with little or no maintenance. However, unreliable systems will incur additional maintenance labor and costs. Managed by power company. Grid reliability varies with location.
Ability to meet needs
  • For wind and solar energy, the actual production is only a fraction of nameplate capacity.
  • Fuel based systems are fully dispatchable
  • Solar panels are simple and reliable, they can provide a little electricity at a reasonable cost.
  • Commentators claim that householders who buy their electricity with green energy tariffs can reduce their carbon usage further than with microgeneration and at a lower cost.
Economy of scale Necessitates mass production of generators which will create an associated environmental impact. Systems are less expensive when produced in quantity. More economical given the larger scale of the generators.

Microgeneration can dynamically balance the supply and demand for electric power, by producing more power during periods of high demand and high grid prices, and less power during periods of low demand and low grid prices. This "hybridized grid" allows both microgeneration systems and large power plants to operate with greater energy efficiency and cost effectiveness than either could alone.

Domestic self-sufficiency

Horizontal Axis Micro-Windmill in Lahore, 1000Watt Rated Output
 
Microgeneration can be integrated as part of a self-sufficient house and is typically complemented with other technologies such as domestic food production systems (permaculture and agroecosystem), rainwater harvesting, composting toilets or even complete greywater treatment systems. Domestic microgeneration technologies include: photovoltaic solar systems, small-scale wind turbines, micro combined heat and power installations, biodiesel and biogas

A small Quietrevolution QR5 Gorlov type vertical axis wind turbine in Bristol, England. Measuring 3 m in diameter and 5 m high, it has a nameplate rating of 6.5 kW to the grid.
 
Private generation decentralizes the generation of electricity and may also centralize the pooling of surplus energy. While they have to be purchased, solar shingles and panels are both available. Capital cost is high, but saves in the long run. With appropriate power conversion, solar PV panels can run the same electric appliances as electricity from other sources.

Passive solar water heating is another effective method of utilizing solar power. The simplest method is the solar (or a black plastic) bag. Set between 1 and 5 gallons out in the sun and allow to heat. Perfect for a quick warm shower.

The ‘breadbox’ heater can be constructed easily with recycled materials and basic building experience. Consisting of a single or array of black tanks mounted inside a sturdy box insulated on the bottom and sides. The lid, either horizontal or angled to catch the most sun, should be well sealed and of a transparent glazing material (glass, fiberglass, or high temp resistant molded plastic). Cold water enters the tank near the bottom, heats and rises to the top where it is piped back into the home.

Ground source heat pumps exploit stable ground temperatures by benefiting from the thermal energy storage capacity of the ground. Typically ground source heat pumps have a high initial cost and are difficult to install by the average homeowner. They use electric motors to transfer heat from the ground with a high level of efficiency. The electricity may come from renewable sources or from external non-renewable sources.

Fuel

Biodiesel is an alternative fuel that can power diesel engines and can be used for domestic heating. Numerous forms of biomass, including soybeans, peanuts, and algae (which has the highest yield), can be used to make biodiesel. Recycled vegetable oil (from restaurants) can also be converted into biodiesel. 

Biogas is another alternative fuel, created from the waste product of animals. Though less practical for most homes, a farm environment provides a perfect place to implement the process. By mixing the waste and water in a tank with space left for air, methane produces naturally in the airspace. This methane can be piped out and burned, and used for a cookfire.

The biogaspro digester provides an easily installed digester suitable for small farms or even large homes. Groups of homes can possible group together to use a digester. 

Government policy

Policymakers were accustomed to an energy system based on big, centralized projects like nuclear or gas-fired power stations. A change of mindsets and incentives are bringing microgeneration into the mainstream. Planning regulations may also require streamlining to facilitate the retrofitting of microgenerating facilities onto homes and buildings.

Most of developed countries, including Canada (Alberta), the United Kingdom, Germany, Poland, Israel and USA have laws allowing microgenerated electricity to be sold into the national grid.

Alberta, Canada

In January 2009, the Government of Alberta‘s Micro-Generation Regulation came into effect, setting rules that allow Albertans to generate their own environmentally friendly electricity and receive credit for any power they send into the electricity grid.

Poland

In December 2014, the Polish government will vote on a bill which calls for microgeneration, as well as large scale wind farms in the Baltic Sea as a solution to cut back on co2 emissions from the country's coal plants as well as to reduce Polish dependence on Russian gas. Under the terms of the new bill, individuals and small businesses which generate up to 40 kW of 'green' energy will receive 100% of market price for any electricity they feed back into the grid, and businesses who set up large-scale offshore wind farms in the Baltic will be eligible for subsidization by the state. Costs of implementing these new policies will be offset by the creation of a new tax on non-sustainable energy use.

United States

The United States has inconsistent energy generation policies across its 50 states. State energy policies and laws may vary significantly with location. Some states have imposed requirements on utilities that a certain percentage of total power generation be from renewable sources. For this purpose, renewable sources include wind, hydroelectric, and solar power whether from large or microgeneration projects. Further, in some areas transferable "renewable source energy" credits are needed by power companies to meet these mandates. As a result, in some portions of the United States, power companies will pay a portion of the cost of renewable source microgeneration projects in their service areas. These rebates are in addition to any Federal or State renewable-energy income-tax credits that may be applicable. In other areas, such rebates may differ or may not be available.

United Kingdom

The UK Government published its Microgeneration Strategy in March 2006, although it was seen as a disappointment by many commentators. In contrast, the Climate Change and Sustainable Energy Act 2006 has been viewed as a positive step. To replace earlier schemes, the Department of Trade and Industry (DTI) launched the Low Carbon Buildings Program in April 2006, which provided grants to individuals, communities and businesses wishing to invest in microgenerating technologies. These schemes have been replaced in turn by new proposals from the Department for Energy and Climate Change (DECC) for clean energy cashback via Feed-In Tariffs for generating electricity from April 2010 and the Renewable Heat Incentive  for generating renewable heat from 28 November 2011.

Feed-In Tariffs are intended to incentivise small-scale (less than 5MW), low-carbon electricity generation. These feed-in tariffs work alongside the Renewables Obligation (RO), which will remain the primary mechanism to incentivize deployment of large-scale renewable electricity generation. The Renewable Heat Incentive (RHI) in intended to incentivise the generation of heat from renewable sources. They also currently offer up to 21p per kWh from December 2011 in the Tariff for photovoltaics plus another 3p for the Export Tariff - an overall figure which could see a household earning back double what they currently pay for their electricity.

On 31 October 2011, the government announced a sudden cut in the feed-in tariff from 43.3p/kWh to 21p/kWh with the new tariff to apply to all new solar PV installations with an eligibility date on or after 12 December 2011.

Prominent British politicians who have announced they are fitting microgenerating facilities to their homes include the Conservative party leader, David Cameron, and the Labour Science Minister, Malcolm Wicks. These plans included small domestic sized wind turbines. Cameron, before becoming Prime Minister in the 2010 general elections, had been asked during an interview on BBC One’s The Politics Show on October 29, 2006, if he would do the same should he get to 10 Downing Street. “If they’d let me, yes,” he replied.

In the December 2006 Pre-Budget Report the government announced that the sale of surplus electricity from installations designed for personal use, would not be subject to Income Tax. Legislation to this effect has been included in the Finance Bill 2007.

In popular culture

Several movies and TV shows such as The Mosquito Coast, Jericho, The Time Machine and Beverly Hills Family Robinson have done a great deal in raising interest in microgeneration among the general public. Websites such as Instructables and Practical Action propose DIY solutions that can lower the cost of microgeneration, thus increasing its popularity. Specialised magazines such as OtherPower and Home Power also provide practical advice and guidance.

Distributed generation

From Wikipedia, the free encyclopedia

Distributed generation, also distributed energy, on-site generation (OSG) or district/decentralized energy is electrical generation and storage performed by a variety of small, grid-connected devices referred to as distributed energy resources (DER).
 
Conventional power stations, such as coal-fired, gas, and nuclear powered plants, as well as hydroelectric dams and large-scale solar power stations, are centralized and often require electric energy to be transmitted over long distances. By contrast, DER systems are decentralized, modular, and more flexible technologies, that are located close to the load they serve, albeit having capacities of only 10 megawatts (MW) or less. These systems can comprise multiple generation and storage components; in this instance they are referred to as hybrid power systems.

DER systems typically use renewable energy sources, including small hydro, biomass, biogas, solar power, wind power, and geothermal power, and increasingly play an important role for the electric power distribution system. A grid-connected device for electricity storage can also be classified as a DER system and is often called a distributed energy storage system (DESS). By means of an interface, DER systems can be managed and coordinated within a smart grid. Distributed generation and storage enables collection of energy from many sources and may lower environmental impacts and improve security of supply.

Microgrids are modern, localized, small-scale grids, contrary to the traditional, centralized electricity grid (macrogrid). Microgrids can disconnect from the centralized grid and operate autonomously, strengthen grid resilience, and help mitigate grid disturbances. They are typically low-voltage AC grids, often use diesel generators, and are installed by the community they serve. Microgrids increasingly employ a mixture of different distributed energy resources, such as solar hybrid power systems, which reduce the amount of emitted carbon significantly.

Overview

Historically, central plants have been an integral part of the electric grid, in which large generating facilities are specifically located either close to resources or otherwise located far from populated load centers. These, in turn, supply the traditional transmission and distribution (T&D) grid that distributes bulk power to load centers and from there to consumers. These were developed when the costs of transporting fuel and integrating generating technologies into populated areas far exceeded the cost of developing T&D facilities and tariffs. Central plants are usually designed to take advantage of available economies of scale in a site-specific manner, and are built as "one-off," custom projects. 

These economies of scale began to fail in the late 1960s and, by the start of the 21st century, Central Plants could arguably no longer deliver competitively cheap and reliable electricity to more remote customers through the grid, because the plants had come to cost less than the grid and had become so reliable that nearly all power failures originated in the grid. Thus, the grid had become the main driver of remote customers’ power costs and power quality problems, which became more acute as digital equipment required extremely reliable electricity. Efficiency gains no longer come from increasing generating capacity, but from smaller units located closer to sites of demand.

For example, coal power plants are built away from cities to prevent their heavy air pollution from affecting the populace. In addition, such plants are often built near collieries to minimize the cost of transporting coal. Hydroelectric plants are by their nature limited to operating at sites with sufficient water flow. 

Low pollution is a crucial advantage of combined cycle plants that burn natural gas. The low pollution permits the plants to be near enough to a city to provide district heating and cooling. 

Distributed energy resources are mass-produced, small, and less site-specific. Their development arose out of:
  1. concerns over perceived externalized costs of central plant generation, particularly environmental concerns;
  2. the increasing age, deterioration, and capacity constraints upon T&D for bulk power;
  3. the increasing relative economy of mass production of smaller appliances over heavy manufacturing of larger units and on-site construction;
  4. Along with higher relative prices for energy, higher overall complexity and total costs for regulatory oversight, tariff administration, and metering and billing.
Capital markets have come to realize that right-sized resources, for individual customers, distribution substations, or microgrids, are able to offer important but little-known economic advantages over central plants. Smaller units offered greater economies from mass-production than big ones could gain through unit size. These increased value—due to improvements in financial risk, engineering flexibility, security, and environmental quality—of these resources can often more than offset their apparent cost disadvantages. DG, vis-à-vis central plants, must be justified on a life-cycle basis. Unfortunately, many of the direct, and virtually all of the indirect, benefits of DG are not captured within traditional utility cash-flow accounting.

While the levelized cost of distributed generation (DG) is typically more expensive than conventional, centralized sources on a kilowatt-hour basis, this does not consider negative aspects of conventional fuels. The additional premium for DG is rapidly declining as demand increases and technology progresses, and sufficient and reliable demand may bring economies of scale, innovation, competition, and more flexible financing, that could make DG clean energy part of a more diversified future.

Distributed generation reduces the amount of energy lost in transmitting electricity because the electricity is generated very near where it is used, perhaps even in the same building. This also reduces the size and number of power lines that must be constructed. 

Typical DER systems in a feed-in tariff (FIT) scheme have low maintenance, low pollution and high efficiencies. In the past, these traits required dedicated operating engineers and large complex plants to reduce pollution. However, modern embedded systems can provide these traits with automated operation and renewable energy, such as solar, wind and geothermal. This reduces the size of power plant that can show a profit.

Grid parity

Grid parity occurs when an alternative energy source can generate electricity at a levelized cost (LCOE) that is less than or equal to the end consumer's retail price. Reaching grid parity is considered to be the point at which an energy source becomes a contender for widespread development without subsidies or government support. Since the 2010s, grid parity for solar and wind has become a reality in a growing number of markets, including Australia, several European countries, and some states in the U.S.

Technologies

Distributed energy resource (DER) systems are small-scale power generation or storage technologies (typically in the range of 1 kW to 10,000 kW) used to provide an alternative to or an enhancement of the traditional electric power system. DER systems typically are characterized by high initial capital costs per kilowatt. DER systems also serve as storage device and are often called Distributed energy storage systems (DESS).

DER systems may include the following devices/technologies:

Cogeneration

Distributed cogeneration sources use steam turbines, natural gas-fired fuel cells, microturbines or reciprocating engines to turn generators. The hot exhaust is then used for space or water heating, or to drive an absorptive chiller for cooling such as air-conditioning. In addition to natural gas-based schemes, distributed energy projects can also include other renewable or low carbon fuels including biofuels, biogas, landfill gas, sewage gas, coal bed methane, syngas and associated petroleum gas.

Delta-ee consultants stated in 2013 that with 64% of global sales, the fuel cell micro combined heat and power passed the conventional systems in sales in 2012. 20.000 units were sold in Japan in 2012 overall within the Ene Farm project. With a Lifetime of around 60,000 hours. For PEM fuel cell units, which shut down at night, this equates to an estimated lifetime of between ten and fifteen years. For a price of $22,600 before installation. For 2013 a state subsidy for 50,000 units is in place.

In addition, molten carbonate fuel cell and solid oxide fuel cells using natural gas, such as the ones from FuelCell Energy and the Bloom energy server, or waste-to-energy processes such as the Gate 5 Energy System are used as a distributed energy resource.

Solar power

Photovoltaics, by far the most important solar technology for distributed generation of solar power, uses solar cells assembled into solar panels to convert sunlight into electricity. It is a fast-growing technology doubling its worldwide installed capacity every couple of years. PV systems range from distributed, residential, and commercial rooftop or building integrated installations, to large, centralized utility-scale photovoltaic power stations

The predominant PV technology is crystalline silicon, while thin-film solar cell technology accounts for about 10 percent of global photovoltaic deployment. In recent years, PV technology has improved its sunlight to electricity conversion efficiency, reduced the installation cost per watt as well as its energy payback time (EPBT) and levelised cost of electricity (LCOE), and has reached grid parity in at least 19 different markets in 2014.

As most renewable energy sources and unlike coal and nuclear, solar PV is variable and non-dispatchable, but has no fuel costs, operating pollution, as well as greatly reduced mining-safety and operating-safety issues. It produces peak power around local noon each day and its capacity factor is around 20 percent.

Wind power

Wind turbines can be distributed energy resources or they can be built at utility scale. These have low maintenance and low pollution, but distributed wind unlike utility-scale wind has much higher costs than other sources of energy. As with solar, wind energy is variable and non-dispatchable. Wind towers and generators have substantial insurable liabilities caused by high winds, but good operating safety. Distributed generation from wind hybrid power systems combines wind power with other DER systems. One such example is the integration of wind turbines into solar hybrid power systems, as wind tends to complement solar because the peak operating times for each system occur at different times of the day and year.

Hydro power

Hydroelectricity is the most widely used form of renewable energy and its potential has already been explored to a large extent or is compromised due to issues such as environmental impacts on fisheries, and increased demand for recreational access. However, using modern 21st century technology, such as wave power, can make large amounts of new hydropower capacity available, with minor environmental impact. 

Modular and scalable Next generation kinetic energy turbines can be deployed in arrays to serve the needs on a residential, commercial, industrial, municipal or even regional scale. Microhydro kinetic generators neither require dams nor impoundments, as they utilize the kinetic energy of water motion, either waves or flow. No construction is needed on the shoreline or sea bed, which minimizes environmental impacts to habitats and simplifies the permitting process. Such power generation also has minimal environmental impact and non-traditional microhydro applications can be tethered to existing construction such as docks, piers, bridge abutments, or similar structures.

Waste-to-energy

Municipal solid waste (MSW) and natural waste, such as sewage sludge, food waste and animal manure will decompose and discharge methane-containing gas that can be collected and used as fuel in gas turbines or micro turbines to produce electricity as a distributed energy resource. Additionally, a California-based company, Gate 5 Energy Partners, Inc. has developed a process that transforms natural waste materials, such as sewage sludge, into biofuel that can be combusted to power a steam turbine that produces power. This power can be used in lieu of grid-power at the waste source (such as a treatment plant, farm or dairy).

Energy storage

A distributed energy resource is not limited to the generation of electricity but may also include a device to store distributed energy (DE). Distributed energy storage systems (DESS) applications include several types of battery, pumped hydro, compressed air, and thermal energy storage. Access to energy storage for commercial applications is easily accessible through programs such as energy storage as a service (ESaaS).

PV storage

Common rechargeable battery technologies used in today's PV systems include, the valve regulated lead-acid battery (lead–acid battery), nickel–cadmium and lithium-ion batteries. Compared to the other types, lead-acid batteries have a shorter lifetime and lower energy density. However, due to their high reliability, low self-discharge (4–6% per year) as well as low investment and maintenance costs, they are currently the predominant technology used in small-scale, residential PV systems, as lithium-ion batteries are still being developed and about 3.5 times as expensive as lead-acid batteries. Furthermore, as storage devices for PV systems are stationary, the lower energy and power density and therefore higher weight of lead-acid batteries are not as critical as for electric vehicles. However, lithium-ion batteries, such as the Tesla Powerwall, have the potential to replace lead-acid batteries in the near future, as they are being intensively developed and lower prices are expected due to economies of scale provided by large production facilities such as the Gigafactory 1. In addition, the Li-ion batteries of plug-in electric cars may serve as future storage devices, since most vehicles are parked an average of 95 percent of the time, their batteries could be used to let electricity flow from the car to the power lines and back. Other rechargeable batteries that are considered for distributed PV systems include, sodium–sulfur and vanadium redox batteries, two prominent types of a molten salt and a flow battery, respectively.

Vehicle-to-grid

Future generations of electric vehicles may have the ability to deliver power from the battery in a vehicle-to-grid into the grid when needed. An electric vehicle network has the potential to serve as a DESS.

Flywheels

An advanced flywheel energy storage (FES) stores the electricity generated from distributed resources in the form of angular kinetic energy by accelerating a rotor (flywheel) to a very high speed of about 20,000 to over 50,000 rpm in a vacuum enclosure. Flywheels can respond quickly as they store and feed back electricity into the grid in a matter of seconds.

Integration with the grid

For reasons of reliability, distributed generation resources would be interconnected to the same transmission grid as central stations. Various technical and economic issues occur in the integration of these resources into a grid. Technical problems arise in the areas of power quality, voltage stability, harmonics, reliability, protection, and control. Behavior of protective devices on the grid must be examined for all combinations of distributed and central station generation. A large scale deployment of distributed generation may affect grid-wide functions such as frequency control and allocation of reserves. As a result, smart grid functions, virtual power plants and grid energy storage such as power to gas stations are added to the grid.

Each distributed generation resource has its own integration issues. Solar PV and wind power both have intermittent and unpredictable generation, so they create many stability issues for voltage and frequency. These voltage issues affect mechanical grid equipment, such as load tap changers, which respond too often and wear out much more quickly than utilities anticipated. Also, without any form of energy storage during times of high solar generation, companies must rapidly increase generation around the time of sunset to compensate for the loss of solar generation. This high ramp rate produces what the industry terms the duck curve (example) that is a major concern for grid operators in the future. Storage can fix these issues if it can be implemented. Flywheels have shown to provide excellent frequency regulation. Short term use batteries, at a large enough scale of use, can help to flatten the duck curve and prevent generator use fluctuation and can help to maintain voltage profile. However, cost is a major limiting factor for energy storage as each technique is prohibitively expensive to produce at scale and comparatively not energy dense compared to liquid fossil fuels. Finally, another necessary method of aiding in integration of photovoltaics for proper distributed generation is in the use of intelligent hybrid inverters

Another approach does not demand grid integration: stand alone hybrid systems.

Stand alone hybrid systems

It is now possible to combine technologies such as photovoltaics, batteries and cogen to make stand alone distributed generation systems.

Recent work has shown that such systems have a low levelized cost of electricity.

Many authors now think that these technologies may enable a mass-scale grid defection because consumers can produce electricity using off grid systems primarily made up of solar photovoltaic technology. For example, the Rocky Mountain Institute has proposed that there may wide scale grid defection. This is backed up by studies in the Midwest.

Cost factors

Cogenerators are also more expensive per watt than central generators. They find favor because most buildings already burn fuels, and the cogeneration can extract more value from the fuel . Local production has no electricity transmission losses on long distance power lines or energy losses from the Joule effect in transformers where in general 8-15% of the energy is lost.

Some larger installations utilize combined cycle generation. Usually this consists of a gas turbine whose exhaust boils water for a steam turbine in a Rankine cycle. The condenser of the steam cycle provides the heat for space heating or an absorptive chiller. Combined cycle plants with cogeneration have the highest known thermal efficiencies, often exceeding 85%. 

In countries with high pressure gas distribution, small turbines can be used to bring the gas pressure to domestic levels whilst extracting useful energy. If the UK were to implement this countrywide an additional 2-4 GWe would become available. (Note that the energy is already being generated elsewhere to provide the high initial gas pressure - this method simply distributes the energy via a different route.)

Microgrid

A microgrid is a localized grouping of electricity generation, energy storage, and loads that normally operates connected to a traditional centralized grid (macrogrid). This single point of common coupling with the macrogrid can be disconnected. The microgrid can then function autonomously. Generation and loads in a microgrid are usually interconnected at low voltage and it can operate in DC, AC, or the combination of both. From the point of view of the grid operator, a connected microgrid can be controlled as if it were one entity. 

Microgrid generation resources can include stationary batteries, fuel cells, solar, wind, or other energy sources. The multiple dispersed generation sources and ability to isolate the microgrid from a larger network would provide highly reliable electric power. Produced heat from generation sources such as microturbines could be used for local process heating or space heating, allowing flexible trade off between the needs for heat and electric power. 

Micro-grids were proposed in the wake of the July 2012 India blackout:
  • Small micro-grids covering 30–50 km radius
  • Small power stations of 5–10 MW to serve the micro-grids
  • Generate power locally to reduce dependence on long distance transmission lines and cut transmission losses.
GTM Research forecasts microgrid capacity in the United States will exceed 1.8 gigawatts by 2018.

Micro-grids have seen implementation in a number of communities over the world. For example, Tesla has implemented a solar micro-grid in the Samoan island of Ta'u, powering the entire island with solar energy. This localized production system has helped save over 100,000 gallons of diesel fuel. It is also able to sustain the island for three whole days if the sun were not to shine at all during that period. This is a great example of how micro-grid systems can be implemented in communities to encourage renewable resource usage and localized production.

To plan and install Microgrids correctly, engineering modelling is needed. Multiple simulation tools and optimization tools exist to model the economic and electric effects of Microgrids. A widely used economic optimization tool is the Distributed Energy Resources Customer Adoption Model (DER-CAM) from Lawrence Berkeley National Laboratory. Another frequently used commercial economic modelling tool is Homer Energy, originally designed by the National Renewable Laboratory. There are also some power flow and electrical design tools guiding the Microgrid developers. The Pacific Northwest National Laboratory designed the public available GridLAB-D tool and the Electric Power Research Institute (EPRI) designed OpenDSS to simulate the distribution system (for Microgrids). A professional integrated DER-CAM and OpenDSS version is available via BankableEnergy. A European tool that can be used for electrical, cooling, heating, and process heat demand simulation is EnergyPLAN from the Aalborg University, Denmark.

Communication in DER systems

  • IEC 61850-7-420 is published by IEC TC 57: Power systems management and associated information exchange. It is one of the IEC 61850 standards, some of which are core Standards required for implementing smart grids. It uses communication services mapped to MMS as per IEC 61850-8-1 standard.
  • OPC is also used for the communication between different entities of DER system.
  • Institute of Electrical and Electronics Engineers IEEE 2030.7 microgrid controller standard. That concept relies on 4 blocks: a) Device Level control (e.g. Voltage and Frequency Control), b) Local Area Control (e.g. data communication), c) Supervisory (software) controller (e.g. forward looking dispatch optimization of generation and load resources), and d) Grid Layer (e.g. communication with utility).
  • A wide variety of complex control algorithms exist, making it difficult for small and residential Distributed Energy Resource (DER) users to implement energy management and control systems. Especially, communication upgrades and data information systems can make it expensive. Thus, some projects try to simplify the control of DER via off-the shelf products and make it usable for the mainstream (e.g. using a Raspberry Pi).

Legal requirements for distributed generation

In 2010 Colorado enacted a law requiring that by 2020 that 3% of the power generated in Colorado utilize distributed generation of some sort.

On 11 October 2017, California Governor Jerry Brown signed into law a bill, SB 338, that makes utility companies plan "carbon-free alternatives to gas generation" in order to meet peak demand. The law requires utilities to evaluate issues such as energy storage, efficiency, and distributed energy resources.