Thermal power station

From Wikipedia, the free encyclopedia
A diagram of a coal-fired thermal power station
Nantong Power Station, a coal-fired power station in Nantong, China
Rooiwal Power Station in South Africa
Geothermal power station in Iceland
Drax Power Station, the world's largest biomass power station, in England
PS10 solar power plant, concentrated solar thermal power station in Andalusia, Spain

A thermal power station, also known as a thermal power plant, is a type of power station in which the heat energy generated from various fuel sources (e.g., coal, natural gas, nuclear fuel, etc.) is converted to electrical energy. The heat from the source is converted into mechanical energy using a thermodynamic power cycle (such as a Diesel cycle, Rankine cycle, Brayton cycle, etc.). The most common cycle involves a working fluid (often water) heated and boiled under high pressure in a pressure vessel to produce high-pressure steam. This high pressure-steam is then directed to a turbine, where it rotates the turbine's blades. The rotating turbine is mechanically connected to an electric generator which converts rotary motion into electricity. Fuels such as natural gas or oil can also be burnt directly in gas turbines (internal combustion), skipping the steam generation step. These plants can be of the open cycle or the more efficient combined cycle type.

The majority of the world's thermal power stations are driven by steam turbines, gas turbines, or a combination of the two. The efficiency of a thermal power station is determined by how effectively it converts heat energy into electrical energy, specifically the ratio of saleable electricity to the heating value of the fuel used. Different thermodynamic cycles have varying efficiencies, with the Rankine cycle generally being more efficient than the Otto or Diesel cycles. In the Rankine cycle, the low-pressure exhaust from the turbine enters a steam condenser where it is cooled to produce hot condensate which is recycled to the heating process to generate even more high pressure steam.

The design of thermal power stations depends on the intended energy source. In addition to fossil and nuclear fuel, some stations use geothermal power, solar energy, biofuels, and waste incineration. Certain thermal power stations are also designed to produce heat for industrial purposes, provide district heating, or desalinate water, in addition to generating electrical power. Emerging technologies such as supercritical and ultra-supercritical thermal power stations operate at higher temperatures and pressures for increased efficiency and reduced emissions. Cogeneration or CHP (Combined Heat and Power) technology, the simultaneous production of electricity and useful heat from the same fuel source, improves the overall efficiency by using waste heat for heating purposes. Older, less efficient thermal power stations are being decommissioned or adapted to use cleaner and renewable energy sources.

Thermal power stations produce 70% of the world's electricity. They often provide reliable, stable, and continuous baseload power supply essential for economic growth. They ensure energy security by maintaining grid stability, especially in regions where they complement intermittent renewable energy sources dependent on weather conditions. The operation of thermal power stations contributes to the local economy by creating jobs in construction, maintenance, and fuel extraction industries. On the other hand, burning of fossil fuels releases greenhouse gases (contributing to climate change) and air pollutants such as sulfur oxides and nitrogen oxides (leading to acid rain and respiratory diseases). Carbon capture and storage (CCS) technology can reduce the greenhouse gas emissions of fossil-fuel-based thermal power stations, however it is expensive and has seldom been implemented. Government regulations and international agreements are being enforced to reduce harmful emissions and promote cleaner power generation.

Types of thermal energy

Almost all coal-fired power stations, petroleum, nuclear, geothermal, solar thermal electric, and waste incineration plants, as well as all natural gas power stations are thermal. Natural gas is frequently burned in gas turbines as well as boilers. The waste heat from a gas turbine, in the form of hot exhaust gas, can be used to raise steam by passing this gas through a heat recovery steam generator (HRSG). The steam is then used to drive a steam turbine in a combined cycle plant that improves overall efficiency. Power stations burning coal, fuel oil, or natural gas are often called fossil fuel power stations. Some biomass-fueled thermal power stations have appeared also. Non-nuclear thermal power stations, particularly fossil-fueled plants, which do not use cogeneration are sometimes referred to as conventional power stations.

Commercial electric utility power stations are usually constructed on a large scale and designed for continuous operation. Virtually all electric power stations use three-phase electrical generators to produce alternating current (AC) electric power at a frequency of 50 Hz or 60 Hz. Large companies or institutions may have their own power stations to supply heating or electricity to their facilities, especially if steam is created anyway for other purposes. Steam-driven power stations have been used to drive most ships in most of the 20th century. Shipboard power stations usually directly couple the turbine to the ship's propellers through gearboxes. Power stations in such ships also provide steam to smaller turbines driving electric generators to supply electricity. Nuclear marine propulsion is, with few exceptions, used only in naval vessels. There have been many turbo-electric ships in which a steam-driven turbine drives an electric generator which powers an electric motor for propulsion.

Cogeneration plants, often called combined heat and power (CHP) facilities, produce both electric power and heat for process heat or space heating, such as steam and hot water.

History

The interior of the Toledo Edison Steam Plant, Toledo, Ohio, approximately 1900

The reciprocating steam engine has been used to produce mechanical power since the 18th century, with notable improvements being made by James Watt. When the first commercially developed central electrical power stations were established in 1882 at Pearl Street Station in New York and Holborn Viaduct power station in London, reciprocating steam engines were used. The development of the steam turbine in 1884 provided larger and more efficient machine designs for central generating stations.

By 1892 the turbine was considered a better alternative to reciprocating engines. Turbines offered higher speeds, more compact machinery, and stable speed regulation allowing for parallel synchronous operation of generators on a common bus. After about 1905, turbines entirely replaced reciprocating engines in almost all large central power stations.

The largest reciprocating engine-generator sets ever built were completed in 1901 for the Manhattan Elevated Railway. Each of seventeen units weighed about 500 tons and was rated 6000 kilowatts; a contemporary turbine set of similar rating would have weighed about 20% as much.

Thermal power generation efficiency

A Rankine cycle with a two-stage steam turbine and a single feed water heater.

The energy efficiency of a conventional thermal power station is defined as saleable energy produced as a percent of the heating value of the fuel consumed. A simple cycle gas turbine achieves energy conversion efficiencies from 20 to 35%. Typical coal-based power plants operating at steam pressures of 170 bar and 570 °C run at efficiency of 35 to 38%, with state-of-the-art fossil fuel plants at 46% efficiency. Combined-cycle systems can reach higher values. As with all heat engines, their efficiency is limited, and governed by the laws of thermodynamics.

The Carnot efficiency dictates that higher efficiencies can be attained by increasing the temperature of the steam. Sub-critical pressure fossil fuel power stations can achieve 36–40% efficiency. Supercritical designs have efficiencies in the low to mid 40% range, with new "ultra critical" designs using pressures above 4,400 psi (30 MPa) and multiple stage reheat reaching 45–48% efficiency. Above the critical point for water of 705 °F (374 °C) and 3,212 psi (22.15 MPa), there is no phase transition from water to steam, but only a gradual decrease in density.

Currently most nuclear power stations must operate below the temperatures and pressures that coal-fired plants do, in order to provide more conservative safety margins within the systems that remove heat from the nuclear fuel. This limits their thermodynamic efficiency to 30–32%. Some advanced reactor designs being studied, such as the very-high-temperature reactor, Advanced Gas-cooled Reactor, and supercritical water reactor, would operate at temperatures and pressures similar to current coal plants, producing comparable thermodynamic efficiency.

The energy of a thermal power station not utilized in power production must leave the plant in the form of heat to the environment. This waste heat can go through a condenser and be disposed of with cooling water or in cooling towers. If the waste heat is instead used for district heating, it is called cogeneration. An important class of thermal power station is that associated with desalination facilities. These are typically found in desert countries with large supplies of natural gas. In these plants freshwater production and electricity are equally important co-products.

Other types of power stations are subject to different efficiency limitations. Most hydropower stations in the United States are about 90 percent efficient in converting the energy of falling water into electricity while the efficiency of a wind turbine is limited by Betz's law, to about 59.3%, and actual wind turbines show lower efficiency.

Electricity cost

The direct cost of electric energy produced by a thermal power station is the result of cost of fuel, capital cost for the plant, operator labour, maintenance, and such factors as ash handling and disposal. Indirect social or environmental costs, such as the economic value of environmental impacts, or environmental and health effects of the complete fuel cycle and plant decommissioning, are not usually assigned to generation costs for thermal stations in utility practice, but may form part of an environmental impact assessment. Those indirect costs belong to the broader concept of externalities.

Boiler and steam cycle

A simplified schematic of a pressurized water reactor

In the nuclear plant field, steam generator refers to a specific type of large heat exchanger used in a pressurized water reactor (PWR) to thermally connect the primary (reactor plant) and secondary (steam plant) systems, which generates steam. In a boiling water reactor (BWR), no separate steam generator is used and water boils in the reactor core.

In some industrial settings, there can also be steam-producing heat exchangers called heat recovery steam generators (HRSG) which utilize heat from some industrial process, most commonly utilizing hot exhaust from a gas turbine. The steam generating boiler has to produce steam at the high purity, pressure and temperature required for the steam turbine that drives the electrical generator.

Geothermal plants do not need boilers because they use naturally occurring steam sources. Heat exchangers may be used where the geothermal steam is very corrosive or contains excessive suspended solids.

A fossil fuel steam generator includes an economizer, a steam drum, and the furnace with its steam generating tubes and superheater coils. Necessary safety valves are located at suitable points to protect against excessive boiler pressure. The air and flue gas path equipment include: forced draft (FD) fan, air preheater (AP), boiler furnace, induced draft (ID) fan, fly ash collectors (electrostatic precipitator or baghouse), and the flue-gas stack.

Feed water heating

The boiler feed water used in the steam boiler is a means of transferring heat energy from the burning fuel to the mechanical energy of the spinning steam turbine. The total feed water consists of recirculated condensate water and purified makeup water. Because the metallic materials it contacts are subject to corrosion at high temperatures and pressures, the makeup water is highly purified before use. A system of water softeners and ion exchange demineralizes produces water so pure that it coincidentally becomes an electrical insulator, with conductivity in the range of 0.3–1.0 microsiemens per centimeter. The makeup water in a 500 MWe plant amounts to perhaps 120 US gallons per minute (7.6 L/s) to replace water drawn off from the boiler drums for water purity management, and to also offset the small losses from steam leaks in the system.

The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s).

A diagram of a boiler feed water deaerator, with a vertical, domed aeration section and a horizontal water storage section.

The water is usually pressurized in two stages, and typically flows through a series of six or seven intermediate feed water heaters, heated up at each point with steam extracted from an appropriate extraction connection on the turbines and gaining temperature at each stage. Typically, in the middle of this series of feedwater heaters, and before the second stage of pressurization, the condensate plus the makeup water flows through a deaerator that removes dissolved air from the water, further purifying and reducing its corrosiveness. The water may be dosed following this point with hydrazine, a chemical that removes the remaining oxygen in the water to below 5 parts per billion (ppb). It is also dosed with pH control agents such as ammonia or morpholine to keep the residual acidity low and thus non-corrosive.

Boiler operation

The boiler is a rectangular furnace about 50 feet (15 m) on a side and 130 feet (40 m) tall. Its walls are made of a web of high pressure steel tubes about 2.3 inches (58 mm) in diameter.

Fuel such as pulverized coal is air-blown into the furnace through burners located at the four corners, or along one wall, or two opposite walls, and it is ignited to rapidly burn, forming a large fireball at the center. The thermal radiation of the fireball heats the water that circulates through the boiler tubes near the boiler perimeter. The water circulation rate in the boiler is three to four times the throughput.

As the water in the boiler circulates it absorbs heat and changes into steam. It is separated from the water inside a drum at the top of the furnace. The saturated steam is introduced into superheat pendant tubes that hang in the hottest part of the combustion gases as they exit the furnace. Here the steam is superheated to 1,000 °F (540 °C) to prepare it for the turbine.

Plants that use gas turbines to heat the water for conversion into steam use boilers known as heat recovery steam generators (HRSG). The exhaust heat from the gas turbines is used to make superheated steam that is then used in a conventional water-steam generation cycle, as described in the gas turbine combined-cycle plants section.

Boiler furnace and steam drum

The water enters the boiler through a section in the convection pass called the economizer. From the economizer it passes to the steam drum and from there it goes through downcomers to inlet headers at the bottom of the water walls. From these headers the water rises through the water walls of the furnace where some of it is turned into steam and the mixture of water and steam then re-enters the steam drum. This process may be driven purely by natural circulation (because the water is the downcomers is denser than the water/steam mixture in the water walls) or assisted by pumps. In the steam drum, the water is returned to the downcomers and the steam is passed through a series of steam separators and dryers that remove water droplets from the steam. The dry steam then flows into the superheater coils.

The boiler furnace auxiliary equipment includes coal feed nozzles and igniter guns, soot blowers, water lancing, and observation ports (in the furnace walls) for observation of the furnace interior. Furnace explosions due to any accumulation of combustible gases after a trip-out are avoided by flushing out such gases from the combustion zone before igniting the coal.

The steam drum (as well as the superheater coils and headers) have air vents and drains needed for initial start up.

Superheater

Fossil fuel power stations often have a superheater section in the steam generating furnace.[citation needed] The steam passes through drying equipment inside the steam drum on to the superheater, a set of tubes in the furnace. Here the steam picks up more energy from hot flue gases outside the tubing, and its temperature is now superheated above the saturation temperature. The superheated steam is then piped through the main steam lines to the valves before the high-pressure turbine.

Nuclear-powered steam plants do not have such sections but produce steam at essentially saturated conditions. Experimental nuclear plants were equipped with fossil-fired superheaters in an attempt to improve overall plant operating cost.

Steam condensing

The condenser condenses the steam from the exhaust of the turbine into liquid to allow it to be pumped. If the condenser can be made cooler, the pressure of the exhaust steam is reduced and efficiency of the cycle increases.

A diagram of a typical water-cooled surface condenser.

The surface condenser is a shell and tube heat exchanger in which cooling water is circulated through the tubes. The exhaust steam from the low-pressure turbine enters the shell, where it is cooled and converted to condensate (water) by flowing over the tubes as shown in the adjacent diagram. Such condensers use steam ejectors or rotary motor-driven exhausts for continuous removal of air and gases from the steam side to maintain vacuum.

For best efficiency, the temperature in the condenser must be kept as low as practical in order to achieve the lowest possible pressure in the condensing steam. Since the condenser temperature can almost always be kept significantly below 100 °C where the vapor pressure of water is much less than atmospheric pressure, the condenser generally works under vacuum. Thus leaks of non-condensible air into the closed loop must be prevented.

Typically the cooling water causes the steam to condense at a temperature of about 25 °C (77 °F) and that creates an absolute pressure in the condenser of about 2–7 kPa (0.59–2.07 inHg), i.e. a vacuum of about −95 kPa (−28 inHg) relative to atmospheric pressure. The large decrease in volume that occurs when water vapor condenses to liquid creates the vacuum that generally increases the efficiency of the turbines.

The limiting factor is the temperature of the cooling water. That is limited by the prevailing average climatic conditions at the power station's location. It may be possible to lower the temperature beyond the turbine limits during winter, causing excessive condensation in the turbine. Plants operating in hot climates may have to reduce output if their source of condenser cooling water becomes warmer. Unfortunately this usually coincides with periods of high electrical demand for air conditioning.

The condenser generally uses either circulating cooling water from a cooling tower to reject waste heat to the atmosphere, or once-through cooling (OTC) water from a river, lake or ocean. In the United States, about two-thirds of power plants use OTC systems, which often have significant adverse environmental impacts. The impacts include thermal pollution and killing large numbers of fish and other aquatic species at cooling water intakes.

A Marley mechanical induced draft cooling tower

The heat absorbed by the circulating cooling water in the condenser tubes must also be removed to maintain the ability of the water to cool as it circulates. This is done by pumping the warm water from the condenser through either natural draft, forced draft or induced draft cooling towers (as seen in the adjacent image) that reduce the temperature of the water by evaporation, by about 11 to 17 °C (52 to 63 °F)—expelling waste heat to the atmosphere. The circulation flow rate of the cooling water in a 500 MW unit is about 14.2 m3/s (500 ft3/s or 225,000 US gal/min) at full load.

The condenser tubes are typically made stainless steel or other alloys to resist corrosion from either side. Nevertheless, they may become internally fouled during operation by bacteria or algae in the cooling water or by mineral scaling, all of which inhibit heat transfer and reduce thermodynamic efficiency. Many plants include an automatic cleaning system that circulates sponge rubber balls through the tubes to scrub them clean without the need to take the system off-line.

The cooling water used to condense the steam in the condenser returns to its source without having been changed other than having been warmed. If the water returns to a local water body (rather than a circulating cooling tower), it is often tempered with cool 'raw' water to prevent thermal shock when discharged into that body of water.

Another form of condensing system is the air-cooled condenser. The process is similar to that of a radiator and fan. Exhaust heat from the low-pressure section of a steam turbine runs through the condensing tubes, the tubes are usually finned and ambient air is pushed through the fins with the help of a large fan. The steam condenses to water to be reused in the water-steam cycle. Air-cooled condensers typically operate at a higher temperature than water-cooled versions. While saving water, the efficiency of the cycle is reduced (resulting in more carbon dioxide per megawatt-hour of electricity).

From the bottom of the condenser, powerful condensate pumps recycle the condensed steam (water) back to the water/steam cycle.

Reheater

Power station furnaces may have a reheater section containing tubes heated by hot flue gases outside the tubes. Exhaust steam from the high-pressure turbine is passed through these heated tubes to collect more energy before driving the intermediate and then low-pressure turbines.

Air path

External fans are provided to give sufficient air for combustion. The Primary air fan takes air from the atmosphere and, first warms the air in the air preheater for better economy. Primary air then passes through the coal pulverizers, and carries the coal dust to the burners for injection into the furnace. The Secondary air fan takes air from the atmosphere and, first warms the air in the air preheater for better economy. Secondary air is mixed with the coal/primary air flow in the burners.

The induced draft fan assists the FD fan by drawing out combustible gases from the furnace, maintaining slightly below atmospheric pressure in the furnace to avoid leakage of combustion products from the boiler casing.

Steam turbine generator

A steam turbine generator consists of a series of steam turbines interconnected to each other and a generator on a common shaft.

Steam turbine

A rotor of a modern steam turbine, used in a power station

There is usually a high-pressure turbine at one end, followed by an intermediate-pressure turbine, and finally one, two, or three low-pressure turbines, and the shaft that connects to the generator. As steam moves through the system and loses pressure and thermal energy, it expands in volume, requiring increasing diameter and longer blades at each succeeding stage to extract the remaining energy. The entire rotating mass may be over 200 metric tons and 100 feet (30 m) long.

It is so heavy that it must be kept turning slowly even when shut down (at 3 rpm) so that the shaft will not bow even slightly and become unbalanced. This is so important that it is one of only six functions of blackout emergency power batteries on site. The other five being emergency lighting, communication, station alarms, generator hydrogen seal system, and turbogenerator lube oil.

For a typical late 20th-century power station, superheated steam from the boiler is delivered through 14–16-inch-diameter (360–410 mm) piping at 2,400 psi (17 MPa; 160 atm) and 1,000 °F (540 °C) to the high-pressure turbine, where it falls in pressure to 600 psi (4.1 MPa; 41 atm) and to 600 °F (320 °C) in temperature through the stage. It exits via 24–26-inch-diameter (610–660 mm) cold reheat lines and passes back into the boiler, where the steam is reheated in special reheat pendant tubes back to 1,000 °F (540 °C). The hot reheat steam is conducted to the intermediate-pressure turbine, where it falls in both temperature and pressure and exits directly to the long-bladed low-pressure turbines and finally exits to the condenser.

Turbo generator

The generator, typically about 30 feet (9 m) long and 12 feet (3.7 m) in diameter, contains a stationary stator and a spinning rotor, each containing miles of heavy copper conductor. There is generally no permanent magnet, thus preventing black starts. In operation it generates up to 21,000 amperes at 24,000 volts AC (504 MWe) as it spins at either 3,000 or 3,600 rpm, synchronized to the power grid.

The rotor spins in a sealed chamber cooled with hydrogen gas, selected because it has the highest known heat transfer coefficient of any gas and for its low viscosity, which reduces windage losses. This system requires special handling during startup, with air in the chamber first displaced by carbon dioxide before filling with hydrogen. This ensures that a highly explosive hydrogen–oxygen environment is not created.

The power grid frequency is 60 Hz across North America and 50 Hz in Europe, Oceania, Asia (Korea and parts of Japan are notable exceptions), and parts of Africa. The desired frequency affects the design of large turbines, since they are highly optimized for one particular speed.

The electricity flows to a distribution yard where transformers increase the voltage for transmission to its destination.

The steam turbine-driven generators have auxiliary systems enabling them to work satisfactorily and safely. The steam turbine generator, being rotating equipment, generally has a heavy, large-diameter shaft. The shaft therefore requires not only supports but also has to be kept in position while running. To minimize the frictional resistance to the rotation, the shaft has a number of bearings. The bearing shells, in which the shaft rotates, are lined with a low-friction material like Babbitt metal. Oil lubrication is provided to further reduce the friction between shaft and bearing surface and to limit the heat generated.

Stack gas path and cleanup

As the combustion flue gas exits the boiler it is routed through a rotating flat basket of metal mesh which picks up heat and returns it to incoming fresh air as the basket rotates. This is called the air preheater. The gas exiting the boiler is laden with fly ash, which are tiny spherical ash particles. The flue gas contains nitrogen along with combustion products carbon dioxide, sulfur dioxide, and nitrogen oxides. The fly ash is removed by fabric bag filters in baghouses or electrostatic precipitators.

Once removed, the fly ash byproduct can sometimes be used in the manufacturing of concrete. This cleaning up of flue gases only occurs in plants that are fitted with the appropriate technology. Still, the majority of coal-fired power stations in the world do not have these facilities. Legislation in Europe has been efficient to reduce flue gas pollution. Japan has been using flue gas cleaning technology for over 30 years and the US has been doing the same for over 25 years. China is now beginning to grapple with the pollution caused by coal-fired power stations.

Where required by law, the sulfur and nitrogen oxide pollutants are removed by stack gas scrubbers which use a pulverized limestone or other alkaline wet slurry to remove those pollutants from the exit stack gas. Other devices use catalysts to remove nitrous oxide compounds from the flue-gas stream. The gas travelling up the flue-gas stack may by this time have dropped to about 50 °C (120 °F). A typical flue-gas stack may be 150–180 metres (490–590 ft) tall to disperse the remaining flue gas components in the atmosphere. The tallest flue-gas stack in the world is 419.7 metres (1,377 ft) tall at the Ekibastuz GRES-2 Power Station in Kazakhstan.

In the United States and a number of other countries, atmospheric dispersion modeling studies are required to determine the flue-gas stack height needed to comply with the local air pollution regulations. The United States also requires the height of a flue-gas stack to comply with what is known as the "good engineering practice" (GEP) stack height. In the case of existing flue gas stacks that exceed the GEP stack height, any air pollution dispersion modeling studies for such stacks must use the GEP stack height rather than the actual stack height.

Carbon capture and storage (CCS) captures carbon dioxide from the flue gas of power plants or other industry, transporting it to an appropriate location where it can be buried securely in an underground reservoir. Between 1972 and 2017, plans were made to add CCS to enough coal and gas power plants to sequester 171 million tonnes of CO
2
per year, but by 2021 over 98% of these plans had failed. Cost, the absence of measures to address long-term liability for stored CO2, and limited social acceptability have all contributed to project cancellations. As of 2024, CCS is in operation at only five power plants worldwide.

Auxiliary systems

Boiler make-up water treatment plant and storage

Since there is continuous withdrawal of steam and continuous return of condensate to the boiler, losses due to blowdown and leakages have to be made up to maintain a desired water level in the boiler steam drum. For this, continuous make-up water is added to the boiler water system. Impurities in the raw water input to the plant generally consist of calcium and magnesium salts which impart hardness to the water. Hardness in the make-up water to the boiler will form deposits on the tube water surfaces which will lead to overheating and failure of the tubes.

The salts have to be removed from the water, and that is done by a water demineralising treatment plant (DM). A DM plant generally consists of cation, anion, and mixed bed exchangers. Any ions in the final water from this process consist essentially of hydrogen ions and hydroxide ions, which recombine to form pure water. Very pure DM water becomes highly corrosive once it absorbs oxygen from the atmosphere because of its very high affinity for oxygen.

The capacity of the DM plant is dictated by the type and quantity of salts in the raw water input. Some storage is essential as the DM plant may be down for maintenance. For this purpose, a storage tank is installed from which DM water is continuously withdrawn for boiler make-up. The storage tank for DM water is made from materials not affected by corrosive water, such as PVC. The piping and valves are generally of stainless steel. Sometimes, a steam blanketing arrangement or stainless steel doughnut float is provided on top of the water in the tank to avoid contact with air. DM water make-up is generally added at the steam space of the surface condenser (i.e., the vacuum side). This arrangement not only sprays the water but also DM water gets deaerated, with the dissolved gases being removed by a de-aerator through an ejector attached to the condenser.

Fuel preparation system

Conveyor system for moving coal (visible at far left) into a power station.

In coal-fired power stations, the raw feed coal from the coal storage area is first crushed into small pieces and then conveyed to the coal feed hoppers at the boilers. The coal is next pulverized into a very fine powder. The pulverizers may be ball mills, rotating drum grinders, or other types of grinders.

Some power stations burn fuel oil rather than coal. The oil must kept warm (above its pour point) in the fuel oil storage tanks to prevent the oil from congealing and becoming unpumpable. The oil is usually heated to about 100 °C before being pumped through the furnace fuel oil spray nozzles.

Boilers in some power stations use processed natural gas as their main fuel. Other power stations may use processed natural gas as auxiliary fuel in the event that their main fuel supply (coal or oil) is interrupted. In such cases, separate gas burners are provided on the boiler furnaces.

Barring gear

Barring gear (or "turning gear") is the mechanism provided to rotate the turbine generator shaft at a very low speed after unit stoppages. Once the unit is "tripped" (i.e., the steam inlet valve is closed), the turbine coasts down towards standstill. When it stops completely, there is a tendency for the turbine shaft to deflect or bend if allowed to remain in one position too long. This is because the heat inside the turbine casing tends to concentrate in the top half of the casing, making the top half portion of the shaft hotter than the bottom half. The shaft therefore could warp or bend by millionths of inches.

This small shaft deflection, only detectable by eccentricity meters, would be enough to cause damaging vibrations to the entire steam turbine generator unit when it is restarted. The shaft is therefore automatically turned at low speed (about one percent rated speed) by the barring gear until it has cooled sufficiently to permit a complete stop.

Oil system

An auxiliary oil system pump is used to supply oil at the start-up of the steam turbine generator. It supplies the hydraulic oil system required for steam turbine's main inlet steam stop valve, the governing control valves, the bearing and seal oil systems, the relevant hydraulic relays and other mechanisms.

At a preset speed of the turbine during start-ups, a pump driven by the turbine main shaft takes over the functions of the auxiliary system.

Generator cooling

While small generators may be cooled by air drawn through filters at the inlet, larger units generally require special cooling arrangements. Hydrogen gas cooling, in an oil-sealed casing, is used because it has the highest known heat transfer coefficient of any gas and for its low viscosity which reduces windage losses. This system requires special handling during start-up, with air in the generator enclosure first displaced by carbon dioxide before filling with hydrogen. This ensures that the highly flammable hydrogen does not mix with oxygen in the air.

The hydrogen pressure inside the casing is maintained slightly higher than atmospheric pressure to avoid outside air ingress, and up to about two atmospheres pressure to improve heat transfer capacity. The hydrogen must be sealed against outward leakage where the shaft emerges from the casing. Mechanical seals around the shaft are installed with a very small annular gap to avoid rubbing between the shaft and the seals on smaller turbines, with labyrinth type seals on larger machines.. Seal oil is used to prevent the hydrogen gas leakage to atmosphere.

The generator also uses water cooling. Since the generator coils are at a potential of about 22 kV, an insulating barrier such as Teflon is used to interconnect the water line and the generator high-voltage windings. Demineralized water of low conductivity is used.

Generator high-voltage system

The generator voltage for modern utility-connected generators ranges from 11 kV in smaller units to 30 kV in larger units. The generator high-voltage leads are normally large aluminium channels because of their high current as compared to the cables used in smaller machines. They are enclosed in well-grounded aluminium bus ducts and are supported on suitable insulators. The generator high-voltage leads are connected to step-up transformers for connecting to a high-voltage electrical substation (usually in the range of 115 kV to 765 kV) for further transmission by the local power grid.

The necessary protection and metering devices are included for the high-voltage leads. Thus, the steam turbine generator and the transformer form one unit. Smaller units may share a common generator step-up transformer with individual circuit breakers to connect the generators to a common bus.

Monitoring and alarm system

Most of the power station operational controls are automatic. At times, manual intervention may be required. Thus, the plant is provided with monitors and alarm systems that alert the plant operators when certain operating parameters are seriously deviating from their normal range.

Battery-supplied emergency lighting and communication

A central battery system consisting of lead–acid cell units is provided to supply emergency electric power, when needed, to essential items such as the power station's control systems, communication systems, generator hydrogen seal system, turbine lube oil pumps, and emergency lighting. This is essential for a safe, damage-free shutdown of the units in an emergency situation.

Circulating water system

To dissipate the thermal load of main turbine exhaust steam, condensate from gland steam condenser, and condensate from Low Pressure Heater by providing a continuous supply of cooling water to the main condenser thereby leading to condensation.

The consumption of cooling water by inland power stations is estimated to reduce power availability for the majority of thermal power stations by 2040–2069.

Transposed letter effect

From Wikipedia, the free encyclopedia

In psychology, the transposed letter effect is a test of how a word is processed when two letters within the word are switched.

The phenomenon takes place when two letters in a word (typically called a base word) switch positions to create a new string of letters that form a new, non-word (typically called a transposed letter non-word or TL non-word). It is a form of priming because the transposed letter non-word is able to activate the lexical representation of its base word. A non-word that is created by transposing letters in a base word is significantly more effective at being a prime for that base word than would be a prime created by exchanging letters from the base word with random letters that were not originally in the base word. For example, the TL non-word stduent would be a more effective prime than would be the non-word stobent for the base word student.

Priming is an effect of implicit memory where exposure to a certain stimulus, event, or experience affects responding to a different stimulus. Typically, the event causes the stimulus to become more salient. The transposed letter effect can be used as a form of priming.

Relevance

With any priming task the purpose is to test the initial stages of processing in order to better understand more complex processing. Psychologists use transposed-letter priming to test how people comprehend word meanings. From these findings, people can begin to understand how people learn, develop and understand language. Transposed-letter priming is used in a wide array of experiments and the reasons for using this method can depend on the particular hypothesis.

Types

Close transpositions

Switching the position of adjacent letters in the base word is a close transposition. This type of transposition creates the greatest priming effect. For example, an effective prime for the word computer would be the TL non-word comptuer.

Distant transpositions

Forming a prime word by switching the position of nonadjacent letters in the base word is a distant transposition. There is significantly less priming effect in a distant transposition than a close transposition, no matter how distant the two letters are from each other. An example for computer would be the non-word ctompuer.

Transposed word effect

Switching the position of adjacent words in a base sentence (rather than word) is a transposed word effect. This transposition creates a great effect. For example, the white cat ran slowly becomes the cat white ran slowly. Participants are shown to take longer and were more error prone to reject the transposed word sentence than control sentence (e.g. the white cat ran helpfully). This type has been used to provide arguments in favour of parallel serial processing.

History

The first study to test the transposed-letter effects was Burner and O'Dowd (1958). However, their experiment did not use priming. They showed participants a word that had two letters switched either at the beginning, in the middle or at the end of the word and they had to determine what the English word was. They measured their response time. Bruner and O'Dowd found that the error at the beginning created the slowest response time, the end was the next slowest and the middle was the fastest. The conclusion to this data was that the beginning and the end were more important for word recognition than the middle. From there, the transposition letter effect was used to test how people process and recognize words using many tasks.

In baboons

A study by Ziegler et al. (2013) demonstrated that baboons also show similar effects in regards to the transposed letter effect as humans. The purpose of the study was to find evidence to suggest that baboons use orthographic processing when reading. Previous research has considered transposed letter effects as strong evidence for orthographic processing (Grainger, 2008). Baboons were asked to classify strings of letters as either words or non-words by selecting certain shapes (for example, a circle for a word and a square for a non-word). The baboons were shown words they had previously learned and non-words. The non-words were created by using four-letter words, previously learned by the baboons, and either transposing the two middle letters or replacing the two middle letters with different letters (double substitute non-words). Baboons classified TL non-words as words significantly more often than double substitute non-words.

Theories affected

Theories challenged by effects of transposed-letter priming

There are a number of theories that have been challenged by the effects shown with transposition-letter priming. These theories mainly have to do with how letters are used to process words.

Slot-based coding theory states that each letter in a word is connected to a particular location, or slot, within that word. One of the major theories that predict letter slots is the interactive activation model created by McClelland and Rumelhart (1981). This model assumes that people are letter-position specific when detecting words, so our recognition of words is based on what letters it contains, where the letters are placed within that word and the length of the word itself. Another example is the Bayesian reader model created by Norris (2006) which also assumes that the letters in a word are associated with their specific location. Many experiments (for example, Perea and Lupker, 2003) have shown if transposed-letter priming is used, (for example, priming judge with jugde) a priming effect will be seen, but if the prime is a word where two letters are changed to other letters (for example, priming judge with jupfe), there is no priming effect. According to the two models discussed, jugde would be assumed to be no more similar to judge than jupfe because the letters are not in the correct slots. In another experiment, TL non-words were more likely to be (incorrectly) classified as actual words than are nonsense control words (Andrews, 1996). Andrew’s results are also inconsistent with the many slot-based coding models because even with two of the letters in the incorrect spot, they read the word as if spelled correctly.

The parallel distributed processing model proposed by Seidenberg and McClelland (1989) also uses a portion of words but instead of letters they are a small group of letters in the same order as in the word. For example, the word judge would have these groupings: _ju, jud, udg, dge, ge_. This predicts that if part of two words match there will be some priming, but this model still depends on the position of the letters to some extent, so it is not compatible with results from transposed-letter priming.

Theories supported by effect of transposed-letter priming

There are a number of theories that are supported by the results shown by the transposed-letter effect.

The SERIOL model (sequential encoding regulated by inputs to oscillations within letter units) described by Whitney (2001) explains processing of words as five levels, or nodes: retinal level, feature level, letter level, bigram level and word level. In the bigram level, the letters detected are turned into a number of pairs. For example, the word cart has the bigrams ca, ar, rt, cr, at and ct. The bigrams that more closely represent the location of letters in the words are given more weight. The pairs are then used to form the word. Within this model, letter location is still a factor but is not a defining feature of word processing, so the transposed-letter effect is consistent with this model.

In the SOLAR model (self-organizing lexical acquisition and recognition) described by Davis (1999) each letter is associated with its own level of activation. The first letter in the word has the highest level of activation and so on until the last letter has the lowest level of activation. In this model, position does describe the level of activation for that particular letter but because the activation is successive, two letters beside each other would have a similar activation level. The SOLAR model is consistent with the results of the transposed-letter effect priming because with this effect experiments have shown priming when two adjacent letters are switched but not when two letters farther apart in the word are switched.

Transposed-letter priming was used by Christianson, Johnson and Rayner (2005) on compound words to test the role of morphemes in word processing. They switched the letters either within the morphemes (for example, snowball to snowblal) or between morphemes (for example, snowball to snobwall) in the primes and found a greater priming effect within the morphemes than between. This supported the theory that morphemes are used during the processing of compound words because the priming effect was only reduced when the letters were switched over the morpheme boundary and were unable to separate into their separate parts.

Internet meme

Typoglycemia (a portmanteau of typo and hypoglycemia) is a neologism for a purported discovery about the cognitive processes involved in reading text. The principle is that readers can comprehend text despite spelling errors and misplaced letters in the words. It is an urban legend and Internet meme that only appears to be correct.

The following example of typoglycemic text was circulated on the Internet in September 2003:

Aoccdrnig to a rscheearch at Cmabrigde Uinervtisy, it deosn't mttaer in waht oredr the ltteers in a wrod are, the olny iprmoetnt tihng is taht the frist and lsat ltteer be at the rghit pclae. The rset can be a toatl mses and you can sitll raed it wouthit porbelm. Tihs is bcuseae the huamn mnid deos not raed ervey lteter by istlef, but the wrod as a wlohe.

Some versions of the text end by saying "Such a cdonition is arppoiately cllaed Typoglycemia :)- Amzanig huh?"

Although the passage is littered with errors, it is still relatively easy to make out the words. However, the example doesn't distort shorter words, and the assertion that only lateral letters matter is untrue.

No such research was carried out at the University of Cambridge. These emails may have been inspired by a letter from Graham Rawlinson of the University of Nottingham to New Scientist in 1999 in which he discusses his 1976 Ph.D. thesis, or perhaps by the research of Thomas R. Jordan's group on the relative influences of the exterior and interior letters of words.

Inertia

From Wikipedia, the free encyclopedia

LAW I. Every object perseveres in its state of rest, or of uniform motion in a right line, except insofar as it is compelled to change that state by forces impressed thereon.

— Isaac Newton, Principia, The Mathematical Principles of Natural Philosophy, Translation by Cohen and Whitman, 1999

In his 1687 work Philosophiæ Naturalis Principia Mathematica, Newton defined inertia as a property:

DEFINITION III. The vis insita, or innate force of matter, is a power of resisting by which every body, as much as in it lies, endeavours to persevere in its present state, whether it be of rest or of moving uniformly forward in a right line.

History and development

Early understanding of inertial motion

Professor John H. Lienhard points out the Mozi – based on a Chinese text from the Warring States period (475–221 BCE) – as having given the first description of inertia. Before the European Renaissance, the prevailing theory of motion in western philosophy was that of Aristotle (384–322 BCE). On the surface of the Earth, the inertia property of physical objects is often masked by gravity and the effects of friction and air resistance, both of which tend to decrease the speed of moving objects (commonly to the point of rest). This misled the philosopher Aristotle to believe that objects would move only as long as force was applied to them. Aristotle said that all moving objects (on Earth) eventually come to rest unless an external power (force) continued to move them. Aristotle explained the continued motion of projectiles, after being separated from their projector, as an (itself unexplained) action of the surrounding medium continuing to move the projectile.

Despite its general acceptance, Aristotle's concept of motion was disputed on several occasions by notable philosophers over nearly two millennia. For example, Lucretius (following, presumably, Epicurus) stated that the "default state" of the matter was motion, not stasis (stagnation). In the 6th century, John Philoponus criticized the inconsistency between Aristotle's discussion of projectiles, where the medium keeps projectiles going, and his discussion of the void, where the medium would hinder a body's motion. Philoponus proposed that motion was not maintained by the action of a surrounding medium, but by some property imparted to the object when it was set in motion. Although this was not the modern concept of inertia, for there was still the need for a power to keep a body in motion, it proved a fundamental step in that direction. This view was strongly opposed by Averroes and by many scholastic philosophers who supported Aristotle. However, this view did not go unchallenged in the Islamic world, where Philoponus had several supporters who further developed his ideas.

In the 11th century, Persian polymath Ibn Sina (Avicenna) claimed that a projectile in a vacuum would not stop unless acted upon.

Theory of impetus

In the 14th century, Jean Buridan rejected the notion that a motion-generating property, which he named impetus, dissipated spontaneously. Buridan's position was that a moving object would be arrested by the resistance of the air and the weight of the body which would oppose its impetus. Buridan also maintained that impetus increased with speed; thus, his initial idea of impetus was similar in many ways to the modern concept of momentum. Despite the obvious similarities to more modern ideas of inertia, Buridan saw his theory as only a modification to Aristotle's basic philosophy, maintaining many other peripatetic views, including the belief that there was still a fundamental difference between an object in motion and an object at rest. Buridan also believed that impetus could be not only linear but also circular in nature, causing objects (such as celestial bodies) to move in a circle. Buridan's theory was followed up by his pupil Albert of Saxony (1316–1390) and the Oxford Calculators, who performed various experiments which further undermined the Aristotelian model. Their work in turn was elaborated by Nicole Oresme who pioneered the practice of illustrating the laws of motion with graphs.

Shortly before Galileo's theory of inertia, Giambattista Benedetti modified the growing theory of impetus to involve linear motion alone:

[Any] portion of corporeal matter which moves by itself when an impetus has been impressed on it by any external motive force has a natural tendency to move on a rectilinear, not a curved, path.

Benedetti cites the motion of a rock in a sling as an example of the inherent linear motion of objects, forced into circular motion.

Classical inertia

According to science historian Charles Coulston Gillispie, inertia "entered science as a physical consequence of Descartes' geometrization of space-matter, combined with the immutability of God." The first physicist to completely break away from the Aristotelian model of motion was Isaac Beeckman in 1614.

The term "inertia" was first introduced by Johannes Kepler in his Epitome Astronomiae Copernicanae (published in three parts from 1617 to 1621). However, the meaning of Kepler's term, which he derived from the Latin word for "idleness" or "laziness", was not quite the same as its modern interpretation. Kepler defined inertia only in terms of resistance to movement, once again based on the axiomatic assumption that rest was a natural state which did not need explanation. It was not until the later work of Galileo and Newton unified rest and motion in one principle that the term "inertia" could be applied to those concepts as it is today.

The principle of inertia, as formulated by Aristotle for "motions in a void", includes that a mundane object tends to resist a change in motion. The Aristotelian division of motion into mundane and celestial became increasingly problematic in the face of the conclusions of Nicolaus Copernicus in the 16th century, who argued that the Earth is never at rest, but is actually in constant motion around the Sun.

Isaac Newton, 1689
Galileo Galilei

Galileo, in his further development of the Copernican model, recognized these problems with the then-accepted nature of motion and, at least partially, as a result, included a restatement of Aristotle's description of motion in a void as a basic physical principle:

A body moving on a level surface will continue in the same direction at a constant speed unless disturbed.

Galileo writes that "all external impediments removed, a heavy body on a spherical surface concentric with the earth will maintain itself in that state in which it has been; if placed in a movement towards the west (for example), it will maintain itself in that movement." This notion, which is termed "circular inertia" or "horizontal circular inertia" by historians of science, is a precursor to, but is distinct from, Newton's notion of rectilinear inertia. For Galileo, a motion is "horizontal" if it does not carry the moving body towards or away from the center of the Earth, and for him, "a ship, for instance, having once received some impetus through the tranquil sea, would move continually around our globe without ever stopping." Galileo later (in 1632) concluded that based on this initial premise of inertia, it is impossible to tell the difference between a moving object and a stationary one without some outside reference to compare it against. This observation ultimately came to be the basis for Albert Einstein to develop the theory of special relativity.

Concepts of inertia in Galileo's writings would later come to be refined, modified, and codified by Isaac Newton as the first of his laws of motion (first published in Newton's work, Philosophiæ Naturalis Principia Mathematica, in 1687):

Every body perseveres in its state of rest, or of uniform motion in a right line, unless it is compelled to change that state by forces impressed thereon.

Despite having defined the concept in his laws of motion, Newton did not actually use the term "inertia.” In fact, he originally viewed the respective phenomena as being caused by "innate forces" inherent in matter which resist any acceleration. Given this perspective, and borrowing from Kepler, Newton conceived of "inertia" as "the innate force possessed by an object which resists changes in motion", thus defining "inertia" to mean the cause of the phenomenon, rather than the phenomenon itself.

However, Newton's original ideas of "innate resistive force" were ultimately problematic for a variety of reasons, and thus most physicists no longer think in these terms. As no alternate mechanism has been readily accepted, and it is now generally accepted that there may not be one that we can know, the term "inertia" has come to mean simply the phenomenon itself, rather than any inherent mechanism. Thus, ultimately, "inertia" in modern classical physics has come to be a name for the same phenomenon as described by Newton's first law of motion, and the two concepts are now considered to be equivalent.

The effect of inertial mass: if pulled slowly, the upper thread breaks (a). If pulled quickly, the lower thread breaks (b).

Relativity

Albert Einstein's theory of special relativity, as proposed in his 1905 paper entitled "On the Electrodynamics of Moving Bodies", was built on the understanding of inertial reference frames developed by Galileo, Huygens and Newton. While this revolutionary theory did significantly change the meaning of many Newtonian concepts such as mass, energy, and distance, Einstein's concept of inertia remained at first unchanged from Newton's original meaning. However, this resulted in a limitation inherent in special relativity: the principle of relativity could only apply to inertial reference frames. To address this limitation, Einstein developed his general theory of relativity ("The Foundation of the General Theory of Relativity", 1916), which provided a theory including noninertial (accelerated) reference frames.

In general relativity, the concept of inertial motion got a broader meaning. Taking into account general relativity, inertial motion is any movement of a body that is not affected by forces of electrical, magnetic, or other origin, but that is only under the influence of gravitational masses. Physically speaking, this happens to be exactly what a properly functioning three-axis accelerometer is indicating when it does not detect any proper acceleration.

Etymology

The term inertia comes from the Latin word iners, meaning idle or sluggish.

Rotational inertia

A quantity related to inertia is rotational inertia (→ moment of inertia), the property that a rotating rigid body maintains its state of uniform rotational motion. Its angular momentum remains unchanged unless an external torque is applied; this is called conservation of angular momentum. Rotational inertia is often considered in relation to a rigid body. For example, a gyroscope uses the property that it resists any change in the axis of rotation.

Misinformation related to birth control

From Wikipedia, the free encyclopedia https://en.wikipedia.org/wiki/Misinformation_related_to_birth_control  ...